Медицинская библиотека · Expert review of respiratory medicine · 2024

Apolipoprotein E in patients with undiagnosed pleural effusion: a prospective diagnostic test accuracy study.

Yang Dan-Ni, Yan Cheng, Yan Li, Niu Yan, Wen Jian-Xun, Hai Ling, Gao Wen-Hui, Wang Ying-Jun, Wang Ya-Fei, Zhou Qianghua, Zheng Wen-Qi, Hu Zhi-De

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Pleural effusion is common in clinical practice, and its differential diagnosis remains challenging for clinicians. This study investigates the diagnostic value of apolipoprotein E (apoE) in patients with undetermined pleural effusion.

METHODS

This prospective, double-blind study enrolled 152 patients with undiagnosed pleural effusion. Their pleural fluid apoE levels were measured, and a receiver operating characteristics (ROC) curve was used to evaluate the diagnostic accuracy of apoE. Decision curve analysis (DCA) was used to assess apoE's net benefit. Subgroup analyses were performed to investigate the effect of age on the diagnostic accuracy of apoE.

RESULTS

Among the included participants, 23 had heart failure (HF). HF patients had the lowest apoE level among pleural effusion patients. The area under the curve (AUC) of apoE for HF was 0.79 (95% CI: 0.69-0.89). At the threshold of 40 mg/L, the sensitivity and specificity of apoE were 0.96 (95% CI: 0.87-1.00) and 0.33 (95% CI: 0.25-0.42), respectively. The decision curve for apoE was above reference lines. The AUC of apoE decreased in older patients.

CONCLUSION

Pleural fluid apoE has moderate diagnostic value for HF and has net benefits in patients with undiagnosed pleural effusion. The diagnostic accuracy of apoE decreases with age.

Для цитирования: Yang Dan-Ni, Yan Cheng, Yan Li, Niu Yan, Wen Jian-Xun, Hai Ling, Gao Wen-Hui, Wang Ying-Jun, Wang Ya-Fei, Zhou Qianghua, Zheng Wen-Qi, Hu Zhi-De. Apolipoprotein E in patients with undiagnosed pleural effusion: a prospective diagnostic test accuracy study.. Expert review of respiratory medicine. 2024. DOI: 10.1080/17476348.2024.2391943.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.