DOI 10.1016/j.acra.2013.02.005
Pressure wire assessment of hemodynamic alterations after chemoembolization of hepatocellular carcinoma.
Аннотация
RATIONALE AND
OBJECTIVES
The end point of chemoembolization for hepatocellular carcinoma is qualitative. We intended to determine the feasibility of measuring intra-arterial pressure changes after chemoembolization and hypothesized that pressures would increase in the distal hepatic artery after the procedure.
MATERIALS AND
METHODS
Before and after chemoembolization, systemic (S) systolic and mean pressures were measured along with celiac (C), lobar (L), and distal (D) hepatic artery pressures with a pressure wire. Corrected pressures were defined as a ratio with S as the denominator to account for intraprocedural S changes. Changes in the systolic and mean corrected pressures at each location (C/S, L/S, and D/S) were evaluated using paired t tests. Pressure changes in patients with and without tumor response using the Modified Response Evaluation Criteria in Solid Tumors were also compared.
RESULTS
Sixteen tumors were treated in 15 patients. One patient had bilobar tumors with separate supplying arteries. The only significant pressure change was systolic D/S (P = .02), while mean D/S approached significance (P = .08). C/S and L/S did not change significantly after chemoembolization. Eleven of 16 patients had a complete response, whereas the other five had a partial response after chemoembolization. When comparing complete to partial responders, no changes in systolic or mean C/S, L/S, or D/S reached statistical significance (all P > .05).
CONCLUSIONS
Measuring change in hepatic artery pressures is feasible. Distal intra-arterial corrected pressures increase significantly after chemoembolization. Further study to determine the ability to predict tumor necrosis at follow-up imaging is warranted.