MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-012-2438-x

Медицинская библиотека · European radiology · 2012

MR-guided radiofrequency ablation using a wide-bore 1.5-T MR system: clinical results of 213 treated liver lesions.

Rempp Hansjörg, Waibel Lorenz, Hoffmann Rüdiger, Claussen Claus D, Pereira Philippe L, Clasen Stephan

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the technical effectiveness, technical success and patient safety of MR-guided radiofrequency (RF) ablation of liver malignancies using a wide-bore 1.5-T MR system.

METHODS

In 110 patients, 56 primary liver lesions and 157 liver metastases were treated in 157 sessions using percutaneous RF ablation. Mean lesion diameter was 20 mm (range 4-54 mm). All planning, procedural and post-interventional control MR investigations were carried out using a wide-bore 1.5-T MR system. Technical success was assessed by a contrast-enhanced MR liver examination immediately after the intervention. Technique effectiveness was assessed by dynamic hepatic MR study 1 month post ablation; mean follow-up period was 24.2 months (range 5-44).

RESULTS

Technical success and technique effectiveness were achieved in 210/213 lesions (98.6 %). In 18/210 lesions (8.6 %), local tumour progression occurred 4-28 months after therapy. Seven of these 18 lesions were treated in a second session achieving complete ablation, 6 other lesions were referred to surgery. Overall RF effectiveness rate was 199/213 (93.4 %); overall therapy success (including surgery) was 205/213 (96.2 %). Two major complications (1.3 %) (bleeding and infected biloma) and 14 (8.9 %) minor complications occurred subsequent to 157 interventions.

CONCLUSION

Wide-bore MR-guided RF ablation is a safe and effective treatment option for liver lesions.

Для цитирования: Rempp Hansjörg, Waibel Lorenz, Hoffmann Rüdiger, Claussen Claus D, Pereira Philippe L, Clasen Stephan. MR-guided radiofrequency ablation using a wide-bore 1.5-T MR system: clinical results of 213 treated liver lesions.. European radiology. 2012. DOI: 10.1007/s00330-012-2438-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.