MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/advs.202411738

Медицинская библиотека · Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024

Wearable Temperature Sensor Enhanced Volatilomics Technique for Swift and Convenient Detection of Latrogenic Botulism.

Li Xiaoyang, Yan Yufei, Hu Chenyi, Wang Jing, Wang Jinlin, Yang Hao, Cui Daxiang, Xin Wenwen, Gao Shan, Jin Han

СтатьяПеревод в очереди

Аннотация

Accurately assessing potential side effects following botulinum neurotoxin (BoNT) injection remains a formidable challenge. To address this issue, an innovative approach is developed that combines a wearable temperature sensor with a sophisticated volatilomics technique, aimed at facilitating the rapid and convenient prediction of potential physical discomfort related to latrogenic botulism. The investigation identifies five volatile organic compounds (VOCs)-acetone, styrene, ethanol, 2-pentanone, and n-butano-as promising markers indicative of BoNT poisoning. Specifically, a handheld breath analyzer, featuring a yttrium stabilized zirconia (YSZ)-based gas sensor array, alongside a wearable temperature sensor integrated with a bio-compatible methacrylated gelatin (GelMA) sensing film, are developed to simultaneously monitor breath signal variations and body temperature fluctuations. Preliminary animal testing validates the effectiveness of the integrated approach, achieving an accuracy exceeding 91.2% in early detection of physical discomfort associated with BoNT poisoning. These promising findings represent a significant advancement towards the early identification of BoNT-related issues, enabling timely intervention and improved management strategies.

Для цитирования: Li Xiaoyang, Yan Yufei, Hu Chenyi, Wang Jing, Wang Jinlin, Yang Hao, Cui Daxiang, Xin Wenwen, Gao Shan, Jin Han. Wearable Temperature Sensor Enhanced Volatilomics Technique for Swift and Convenient Detection of Latrogenic Botulism.. Advanced science (Weinheim, Baden-Wurttemberg, Germany). 2024. DOI: 10.1002/advs.202411738.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.