MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10554-013-0322-7

Медицинская библиотека · The international journal of cardiovascular imaging · 2013

CT signs of right ventricular dysfunction correlated with echocardiography-derived pulmonary arterial systolic pressure: incremental value of the pulmonary arterial diameter index.

Lim Soyeoun, Lee Heon, Lee Soo Jeong, Kim Jae Kyun, Suh Jon, Lee Eun Hye, Paik Sang Hyun

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

To investigate and compare the potential of right to left ventricular volume (RVV/LVV) and diameter ratios (RVD/LVD) for the prediction of pulmonary arterial hypertension (PH) over 40 mmHg, and then to evaluate the incremental value of the pulmonary artery diameter index (PADi; PAD/body surface area) in the prediction of PH over 40 mHg. We correlated the followings on chest CT with same-day echocardiography-derived pulmonary arterial systolic pressure (PASP) in 139 patients (64.8 ± 15.4 years; 63 male): PADi, RVD/LVD on axial (RVD axial/LVD axial) and four chamber (RVD 4CH/LVD 4CH) views, and RVV/LVV. Those were then adjusted (multiplied) by PADi. Areas under the curves (AUC) for predicting PASP > 40 mmHg were calculated. All patients had undergone non-ECG-gated, contrast enhanced chest CT on a 64-slice multi-detector CT system. The correlation of PASP with RVV/LVV (R(2) = 0.45) was stronger than with RVD axial/LVD axial (R(2) = 0.28) and RVD 4CH/LVD 4CH (R(2) = 0.34). When adjusted by PADi, the correlation improved; R(2) = 0.55, 0.41 and 0.47, respectively. The AUC of adjusted RVV/LVV was significantly higher than those of other CT measurements (P < 0.05) excluding adjusted RVD 4CH/LVD 4CH (P = 0.08). With 18.80 as the cutoff, its sensitivity and specificity for predicting PH > 40 mmHg were 83 and 87 %, respectively. Ventricular volume is superior to ventricular diameter ratios in the prediction of PH > 40 mmHg with better correlation with PASP. PADi adds incremental value to these measurements in the prediction of PH > 40 mmHg. Of those, adjusted RVV/LVV is most reliable and predicts PH > 40 mmHg with fairly high sensitivity and specificity.

Для цитирования: Lim Soyeoun, Lee Heon, Lee Soo Jeong, Kim Jae Kyun, Suh Jon, Lee Eun Hye, Paik Sang Hyun. CT signs of right ventricular dysfunction correlated with echocardiography-derived pulmonary arterial systolic pressure: incremental value of the pulmonary arterial diameter index.. The international journal of cardiovascular imaging. 2013. DOI: 10.1007/s10554-013-0322-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.