Are Slow Waves of Intracranial Pressure Suppressed by General Anaesthesia?

Lalou Despina Afroditi, Czosnyka Marek, Donnelly Joseph, Lavinio Andrea, Pickard John D, Garnett Matthew, Czosnyka Zofia

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Slow waves of intracranial pressure (ICP) are spontaneous oscillations with a frequency of 0.3-4 cycles/min. They are often associated with pathological conditions, following vasomotor activity in the cranial enclosure. This study quantifies the effects of general anaesthesia (GA) on the magnitude of B-waves compared with natural sleep and the conscious state.

MATERIALS AND

METHODS

Four groups of 30 patients each were formed to assess the magnitude of slow waves. Group A and group B consisted of normal pressure hydrocephalus (NPH) patients, each undergoing cerebrospinal fluid (CSF) infusion studies, conscious and under GA respectively. Group C comprised conscious, naturally asleep hydrocephalic patients undergoing overnight ICP monitoring; group D, which included deeply sedated head injury patients monitored in the intensive care unit (ICU), was compared with group C.

RESULTS

The average amplitude for group A patients was higher (0.23 ± 0.10 mmHg) than that of group B (0.15 ± 0.10 mmHg; p = 0.01). Overnight magnitude of slow waves was higher in group C (0.20 ± 0.13 mmHg) than in group D (0.11 ± 0.09 mmHg; p = 0.002).

CONCLUSION

Slow waves of ICP are suppressed by GA and deep sedation. When using slow waves in clinical decision-making, it is important to consider the patients' level of consciousness to avoid incorrect therapeutic and management decisions.

Для цитирования: Lalou Despina Afroditi, Czosnyka Marek, Donnelly Joseph, Lavinio Andrea, Pickard John D, Garnett Matthew, Czosnyka Zofia. Are Slow Waves of Intracranial Pressure Suppressed by General Anaesthesia?. Acta neurochirurgica. Supplement. 2018. DOI: 10.1007/978-3-319-65798-1_27.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.