DOI 10.1097/00006982-200410000-00015
Retinal function after subconjunctival injection of carboplatin in fibrin sealant.
Аннотация
PURPOSE: To evaluate retinal function in a rabbit model after subconjunctival delivery of carboplatin in balanced saline solution (BSS) or fibrin sealant to determine possible retinal toxicity.
METHODS
One group of rabbits (n = 5) received a unilateral subconjunctival injection of 12.2 +/- 1.0 mg/mL of carboplatin (Paraplatin) in BSS. Another group of rabbits (n = 5) received 25.1 +/- 7.7 mg/mL of carboplatin in fibrin sealant (Hemaseel APR). Rabbits injected with fibrin sealant only (n = 2) and BSS only (n = 2) were used as control groups. Electroretinographic recordings consisted of a series of intensities presented under dark- and light-adapted conditions. Electroretinograms were recorded before the injection (baseline) and 2 days, 1, 2, and 3 weeks after the injection. After 3 weeks, all rabbit eyes were obtained for histopathologic examination.
RESULTS
Transient reductions in the dark-adapted b-wave amplitudes were noted 2 days after treatment for eyes injected with carboplatin compared with the vehicle-only treatment groups. Other treatment groups and postinjection time points showed no significant changes from baseline. Retinal structure and thickness were normal 3 weeks after treatment for all treatment groups.
CONCLUSION
Subconjunctival delivery of carboplatin in fibrin sealant or BSS does not have a toxic effect on retinal function or structure in a non-tumor-bearing rabbit model at the doses used in this study at 3 weeks' follow-up.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.