m+Medelevator.RU
← Поиск публикаций
Journal of cardiovascular electrophysiology · 2015

Acute and Long-Term Outcomes of Catheter Ablation of Atrial Fibrillation Using the Second-Generation Cryoballoon versus Open-Irrigated Radiofrequency: A Multicenter Experience.

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Aryana Arash, Singh Sheldon M, Kowalski Marcin, Pujara Deep K, Cohen Andrew I, Singh Steve K, Aleong Ryan G, Banker Rajesh S, Fuenzalida Charles E, Prager Nelson A, Bowers Mark R, D'Avila André, O'Neill Padraig Gearoid

Аннотация

INTRODUCTION: There are limited comparative data on catheter ablation of atrial fibrillation (CAAF) using the second-generation cryoballoon (CB-2) versus point-by-point radiofrequency (RF). This study examines the acute/long-term CAAF outcomes using these 2 strategies.

METHODS AND RESULTS: In this multicenter, retrospective, nonrandomized analysis, procedural and clinical outcomes of 1,196 patients (76% with paroxysmal AF) undergoing CAAF using CB-2 (n = 773) and open-irrigated, non-force sensing RF (n = 423) were evaluated. Pulmonary vein isolation was achieved in 98% with CB-2 and 99% with RF (P = 0.168). CB-2 was associated with shorter ablation time (40 ± 14 min vs. 66 ± 26 min; P < 0.001) and procedure time (145 ± 49 minutes vs. 188 ± 42 minutes; P < 0.001), but greater fluoroscopic utilization (29 ± 13 minutes vs. 23 ± 14 minutes; P < 0.001). While transient (7.6% vs. 0%; P < 0.001) and persistent (1.2% vs. 0%; P = 0.026) phrenic nerve palsy occurred exclusively with CB-2, other adverse event rates were similar between CB-2 (1.6%) and RF (2.6%); P = 0.207. However, freedom from AF/atrial flutter/tachycardia at 12 months following a single procedure without antiarrhythmic therapy was greater with CB-2 (76.6%) versus RF (60.4%); P < 0.001. While this difference was evident in patients with paroxysmal AF (P < 0.001), it did not reach significance in those with persistent AF (P = 0.089). Additionally, CB-2 was associated with reduced long-term need for antiarrhythmic therapy (16.7% vs. 22.0%; P = 0.024) and repeat ablations (14.6% vs. 24.1%; P < 0.001).

CONCLUSION: In this multicenter, retrospective, nonrandomized study, CAAF using CB-2 coupled with RF as occasionally required was associated with greater freedom from atrial arrhythmias at 12 months following a single procedure without antiarrhythmic therapy when compared to open-irrigated, non-force sensing RF, alone.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты