MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circep.113.000196

Медицинская библиотека · Circulation. Arrhythmia and electrophysiology · 2013

Pulmonary antrum radial-linear ablation for paroxysmal atrial fibrillation: interim analysis of a multicenter trial.

Zhao Xue, Zhang Jiayou, Hu Jianqiang, Liao Dening, Zhu Yinxiang, Mei Xiang, Sheng Jun, Yuan Fang, Gui Yanping, Lu Wenliang, Dai Li, Guo Xingui, Xu Yawei, Zhang Yanzhou, He Ben, Liu Zhenguo

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Substrate abnormality in pulmonary vein (PV) antrum plays a critical role in mechanism of atrial fibrillation (AF). The present study compares the strategy of PV antrum radial-linear (PAR) ablation to encircling PV isolation for paroxysmal AF.

METHODS AND

RESULTS

A total of 86 patients with paroxysmal AF were randomly assigned to PAR ablation group or PV isolation group. The average procedure time was 161±21 minutes in PAR ablation group and 199±39 minutes in PV isolation group (P<0.01). The average fluoroscopy time was 25±5 minutes in PAR ablation group and 32±9 minutes in PV isolation group (P<0.001). At 14 (15-12) months of follow-up after single procedure, 31 of 42 (74%) patients in PAR ablation group and 22 of 44 patients (50%) in PV isolation group had no recurrence of AF off antiarrhythmic drug (P=0.0249); and 36 of 42 patients (86%) in PAR ablation group and 26 of 44 patients (59%) in PV isolation group had no recurrence of AF with antiarrhythmic drug (P=0.006). In addition, PAR ablation resulted in greater reduction of left atrial diameter than encircling PV isolation. Multivariable Cox regression analysis showed that only ablation strategy was independently associated with AF recurrence (hazard ratio, 0.31; 95% confidence interval, 0.12-0.78; P=0.013). No major adverse event related to the procedures occurred.

CONCLUSIONS

This study suggests that PAR ablation is a potentially effective strategy for treatment of paroxysmal AF warranting further investigation.

CLINICAL TRIAL REGISTRATION: URL: http://www.chictr.org; Unique identifier: ChiCTR-TRC-11001191.

Для цитирования: Zhao Xue, Zhang Jiayou, Hu Jianqiang, Liao Dening, Zhu Yinxiang, Mei Xiang, Sheng Jun, Yuan Fang, Gui Yanping, Lu Wenliang, Dai Li, Guo Xingui, Xu Yawei, Zhang Yanzhou, He Ben, Liu Zhenguo. Pulmonary antrum radial-linear ablation for paroxysmal atrial fibrillation: interim analysis of a multicenter trial.. Circulation. Arrhythmia and electrophysiology. 2013. DOI: 10.1161/circep.113.000196.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.