MedElevator Войти в исследования
← Поиск публикаций

DOI 10.22336/rjo.2021.72

Медицинская библиотека · Romanian journal of ophthalmology · 2021

Efficacy and safety of Ab interno XEN gel implant after a failed filtering surgery.

Franco Fabrizio Gaetano Saverio, Branchetti Marco, Spagnuolo Vito, Piergentili Marco, Serino Federica, De Vitto Maria Luce, Bertelli Enrico, Virgili Gianni, Giasanti Fabrizio

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

Purpose: To evaluate the efficacy and safety of Ab interno XEN gel stent in patients with open angle glaucoma who underwent a previous failed filtering surgery.

Methods

A retrospective, observational, multi-centered and descriptive cohort study was conducted from January 2019 to February 2020 on patients with primary open angle glaucoma (POAG) who underwent XEN gel stent implant after a failed filtering surgical procedure. Main parameters evaluated were: changes in IOP measured with Goldmann applanation tonometer, number of anti-glaucomatous eye drops, postoperative complications, and necessity of further surgical procedures. The quantification of quality of life was obtained from the VFQ-25 questionnaire. A descriptive analysis based on pre- post- and intra-operative data was carried out.

Results

In all patients included in the study (6 patients for a total of 7 eyes), IOP dropped during the follow up time. We found a mean percentage reduction of -41.5% at 9 months compared to the preoperative data (baseline). IOP lowered from 21.71 ± 4.64 mmHg to 9 ± 3,21 mmHg 1 day after the operation, 11 ± 3.21 at 1 week, 11.42 ± 1.81 mmHg at 1 month, 12.42 ± 3.10 mmHg at 3 months, 13.57 ± 3.45 at 6 months, 12.71 ± 1.79 at 9 months. In 71.4%, the procedure turned out to be complication free and only one case required needling of the bleb in order to achieve optimal intraocular pressure control. A total of 71.4% patients reached a medication free regimen with a percentage of reduction in the mean number of drugs needed of -88.9%.

Conclusion

In our experience, XEN gel stent implant performed in Caucasian patients with POAG and a history of failed filtrating surgery, showed to be an effective and safe procedure.

Для цитирования: Franco Fabrizio Gaetano Saverio, Branchetti Marco, Spagnuolo Vito, Piergentili Marco, Serino Federica, De Vitto Maria Luce, Bertelli Enrico, Virgili Gianni, Giasanti Fabrizio. Efficacy and safety of Ab interno XEN gel implant after a failed filtering surgery.. Romanian journal of ophthalmology. 2021. DOI: 10.22336/rjo.2021.72.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.