MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2021.11.029

Медицинская библиотека · American journal of ophthalmology · 2021

Optical Microangiography and Progressive Ganglion Cell-Inner Plexiform Layer Loss in Primary Open-Angle Glaucoma.

Rao Harsha L, Dasari Srilakshmi, Puttaiah Narendra K, Pradhan Zia S, Moghimi Sasan, Mansouri Kaweh, Webers Carroll A B, Weinreb Robert N

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the association between optical microangiography (OMAG) measurements and progressive ganglion cell-inner plexiform layer (GCIPL) loss in patients with primary open-angle glaucoma (POAG).

DESIGN

Prospective case series.

METHODS

Sixty-three eyes of 38 patients with POAG were studied for ≥2 years and with ≥ 3 optical coherence tomography examinations. Only those hemifields with mild to moderate functional damage at baseline (106 hemifields) were included in the analysis. OMAG imaging was performed at the baseline visit. The effects of clinical parameters (age, gender, central corneal thickness, presence of disc hemorrhage, and mean and fluctuation of intraocular pressure), baseline mean deviation, retinal nerve fiber layer, and GCIPL thickness and baseline OMAG measurements (peripapillary and macular perfusion density [PD] and vessel density [VD]) on the rate of change of GCIPL thickness were evaluated using linear mixed models.

RESULTS

Average (± standard deviation) mean deviation, quadrant retinal nerve fiber layer, and sector GCIPL thickness of the analyzed hemifields respectively at baseline were -5.2 ± 2.8 dB, 94.5 ± 20.0 µm, and 72.4 ± 8.7 µm, respectively. Peripapillary PD and VD in the quadrant were 43.1% ± 7.0% and 17.0 ± 2.6 mm/mm2, respectively. Macular PD and VD in the quadrant were 37.2% ± 6.9% and 15.1 ± 2.6 mm/mm2, respectively. Rate of sector GCIPL change was -0.97 ± 0.15 µm per year. Multivariate mixed models showed that lower peripapillary PD (coefficient 0.04, P = .01) and VD (coefficient 0.09, P = .05) were significantly associated with a faster rate of GCIPL loss.

CONCLUSIONS

Lower baseline peripapillary OMAG measurements were significantly associated with a faster rate of GCIPL loss in patients with mild to moderate POAG.

Для цитирования: Rao Harsha L, Dasari Srilakshmi, Puttaiah Narendra K, Pradhan Zia S, Moghimi Sasan, Mansouri Kaweh, Webers Carroll A B, Weinreb Robert N. Optical Microangiography and Progressive Ganglion Cell-Inner Plexiform Layer Loss in Primary Open-Angle Glaucoma.. American journal of ophthalmology. 2021. DOI: 10.1016/j.ajo.2021.11.029.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.