m+Medelevator.RU
← Поиск публикаций
Herzschrittmachertherapie & Elektrophysiologie · 2021

Radiation exposure in cryoballoon ablation compared to radiofrequency ablation with three-dimensional electroanatomic mapping in atrial fibrillation patients.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ali Ahmed Nabil, Ali Hisham Kamal-Eldin, Khalid Said Abd-El-Hafeez, El-Khouly Wael Ali

Аннотация

BACKGROUND: Catheter ablation for atrial fibrillation (AF) has become an established treatment to control symptoms. AF ablation either by cryoballoon or radiofrequency using three-dimensional (3D) electroanatomical mapping exposes patients and medical staff to increased doses of radiation.

AIM: To compare radiation exposure in patients during cryoballoon ablation compared to 3D electro-anatomic mapping catheter ablation in AF patients.

METHODS: A total of 30 patients referred for AF ablation underwent full history taking, 12-lead ECG, echocardiogram, and pulmonary vein isolation either by 3D mapping system or cryoballoon. Procedure duration and fluoroscopy time were collected and analyzed. Radiation exposure was measured using thermoluminescent dosimeters placed at different sites related to patients and medical staff.

RESULT: The procedural time was statistically significantly longer with 3D mapping compared to cryoballoon but showed no significant difference regarding fluoroscopy time. There was a significantly higher radiation skin dose at the right scapular area in the cryoballoon ablation group, in addition to higher peak skin dose compared to the 3D mapping ablation group. There was no statistically significant correlation between peak skin doses and fluoroscopy duration but a statistically significant correlation between peak skin dose and usage of high frame rate and the high dose area product.

CONCLUSION: Cryoballoon ablation was found to be associated with higher peak skin radiation doses especially in the right scapular area. Knowing dose area product and peak skin dose is more important than fluoroscopy time alone.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты