Association between the locations of non-pulmonary vein triggers and ablation outcomes in repeat procedures after cryoballoon ablation of paroxysmal atrial fibrillation.

Takamiya Tomomasa, Inaba Osamu, Nitta Junichi, Sato Akira, Inamura Yukihiro, Murata Kazuya, Ikenouchi Takashi, Kono Toshikazu, Nitta Giichi, Takahashi Yoshihide, Goya Masahiko, Sasano Tetsuo

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: We examined the characteristics of non-pulmonary vein (PV) triggers in repeat ablation after cryoballoon ablation for paroxysmal atrial fibrillation (PAF).

METHODS

This study evaluated 119 patients undergoing a second ablation procedure for recurrent atrial tachyarrhythmia (ATA) after cryoballoon PV isolation (CB-PVI) for PAF.

RESULTS

Fifty-three of 119 (45%) patients had PV reconnection. All reconnected PVs were isolated. No non-PV triggers were elicited in 42/119 (35%) patients (NNPV group). In 77/119 (65%) patients, 139 isoproterenol-induced non-PV triggers, including 45 triggers that initiated AF, were identified. Non-PV triggers initiating AF were observed at the superior vena cava (SVC), left atrial posterior wall (LAPW) including the PV antra, interatrial septum, right atrium, left atrial appendage/mitral anulus, and coronary sinus in 14 (12%), 10 (8%), 8 (7%), 7 (6%), 4 (3%), and 2 (2%) patients, respectively. Non-PV triggers originated from only the SVC and/or LAPW including the PV antra, and the SVC and/or LAPW was isolated in 18/119 (15%) patients (SVC/LAPW group). Non-PV triggers originating from other sites were focally ablated in 59/119 (50%) patients (OS group). During a median 461 days of follow-up, 39/42 (93%), 17/18 (94%), and 38/59 (64%) patients in the NNPV, SVC/LAPW, and OS groups, respectively, remained ATA recurrence-free. The recurrence rate was higher in the OS group than in the NNPV (P = 0.005) or SVC/LAPW groups (P = 0.042).

CONCLUSIONS

Over half of patients had non-PV triggers at subsequent ablation after CB-PVI. Non-PV triggers from the SVC/LAPW can be eliminated more successfully than triggers from other sites.

Для цитирования: Takamiya Tomomasa, Inaba Osamu, Nitta Junichi, Sato Akira, Inamura Yukihiro, Murata Kazuya, Ikenouchi Takashi, Kono Toshikazu, Nitta Giichi, Takahashi Yoshihide, Goya Masahiko, Sasano Tetsuo. Association between the locations of non-pulmonary vein triggers and ablation outcomes in repeat procedures after cryoballoon ablation of paroxysmal atrial fibrillation.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2020. DOI: 10.1007/s10840-020-00913-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.