Comparison of clinical outcomes following small incision lenticule extraction performed with the visumax 800 versus visumax 500 femtosecond laser.

Kim Bu Ki, Chung Young Taek

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

This study compared clinical outcomes between small incision lenticule extraction (SMILE) procedures performed with the Visumax 800 and Visumax 500 femtosecond lasers. We compared the clinical outcomes of 100 eyes of 50 patients who underwent SMILE using the Visumax 800 (SMILE Pro group) and 100 eyes of 50 patients who underwent SMILE using the Visumax 500 femtosecond laser (SMILE group). Outcomes were assessed at a 3-month follow-up, including standard visual outcomes, optic zone decentration, and corneal higher-order aberrations (HOAs). The mean lenticule creation time was significantly shorter in the SMILE Pro group (10.33 ± 0.82 s) than the SMILE group (28.27 ± 2.34 s, P < 0.001). At 3 months postoperatively, the groups had no significant differences in uncorrected or corrected distance visual acuity, residual refractive errors, or corneal HOAs. However, the optic zone decentration was significantly smaller in the SMILE Pro group than in the SMILE group (P < 0.001), and the vertical coma induction was significantly lower in the SMILE Pro group compared with the SMILE group (P = 0.034), suggesting that the Visumax 800 provides enhanced centration accuracy, reduced vertical coma induction, and faster lenticule creation, demonstrating comparable efficacy, safety, and predictability to the Visumax 500.

Для цитирования: Kim Bu Ki, Chung Young Taek. Comparison of clinical outcomes following small incision lenticule extraction performed with the visumax 800 versus visumax 500 femtosecond laser.. Scientific reports. 2025. DOI: 10.1038/s41598-025-98041-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.