Laux Christoph J, Villefort Christina, El Nashar Rany, Farei-Campagna Jan M, Grubhofer Florian, Bouaicha Samy, Gerber Christian, Meyer Dominik C, Wieser Karl

Аннотация

BACKGROUND: The treatment of unstable (Neer type IIB and V) extra-articular distal clavicle fractures remains challenging, especially when encountering a small lateral fragment which does not allow for sufficient screw purchase. It was the purpose of this study to present the clinical and radiologic outcome of a consecutive series of patients treated by a stand-alone coracoclavicular stabilization using a so-called cow-hitch technique with a suture anchor.

METHODS: Nineteen patients were treated with a specific surgical technique for distal clavicle fractures (11 left, 8 right) with either rupture or bony avulsion of the coracoclavicular ligaments. Fourteen patients were examined in our outpatient clinic for the purpose of this study after a mean follow-up of 5 years (1-12.2 years). The examination included scoring according to Constant Murley score (CMS), the American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES), the Subjective Shoulder Value (SSV), and follow-up radiographs. Two additional patients were amenable to a telephone interview.

RESULTS: All patients reported very good subjective results, with a mean SSV of 92% and a mean ASES score of 96%. The CMS resulted in average absolute values of 92 points. Fractures consolidated in 95% of cases. One patient developed an asymptomatic pseudarthrosis. The coracoclavicular distance was restored from 21 mm preoperatively to 11 mm at the final follow-up and finally showed an average side-to-side difference of +1.8 mm. Sports activities were fully resumed after an average of 4.7 months.

CONCLUSION: The coracoclavicular stand-alone cow-hitch suture repair for unstable distal clavicle fractures is a minimally invasive fixation technique without prominent hardware that allows for an anatomic reduction and stable fixation with a low complication and high bony union rate. Both radiographic and clinical long-term results are very satisfactory.