DOI 10.1111/crj.13654

Медицинская библиотека · The clinical respiratory journal · 2023

A retrospective comparison between digital to conventional drainage systems for secondary spontaneous pneumothorax related to diffuse interstitial lung disease.

Shikano Kohei, Abe Mitsuhiro, Hirama Ryutaro, Kitahara Shinsuke, Maruyama Kanae, Horiuchi Dai, Sakuma Noriko, Ishii Daisuke, Kawasaki Takeshi, Nakamura Hidenori, Suzuki Takuji

ОбзорСтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Secondary spontaneous pneumothorax (SSP) occurs as one of the complications associated with interstitial pneumonia (IP). Chest drainage is performed when there is a large volume of air in the pleural space. Notably, SSP with IP (SSP-IP) is frequently not curable by chest drainage only. A digital drainage system (DDS) provides an objective evaluation of air leakage and maintains a pre-determined negative pressure, compared to an analog drainage system (ADS). Few studies have reported the effectiveness of DDS in the treatment of SSP-IP. This study aimed to assess the usefulness of DDS for SSP-IP.

METHODS

This retrospective study included patients with SSP-IP who had undergone chest drainage. We reviewed the included patients' medical records, laboratory data, computed tomography findings, and pulmonary function data.

RESULTS

DDS was used in 24 patients and ADS in 49 patients. The mean duration of chest drainage was 11.4 ± 1.9 days in the DDS group and 14.2 ± 1.3 days in the ADS group, which was not significantly different (p = 0.218). Surgery, pleurodesis, and/or factor XIII administration were performed in 40 patients. Additionally, five (20.8%) patients in the DDS group and nine (18.4%) in the ADS group had a recurrence of pneumothorax within 4 weeks (p = 1.000). One patient (14%) in the DDS group and six (12.2%) in the ADS group (p = 0.414) were cured of pneumothorax but later died.

CONCLUSION

DDS did not demonstrate a significant difference in the shortening of chest drainage duration. Further study is needed to validate the results of this study.

Для цитирования: Shikano Kohei, Abe Mitsuhiro, Hirama Ryutaro, Kitahara Shinsuke, Maruyama Kanae, Horiuchi Dai, Sakuma Noriko, Ishii Daisuke, Kawasaki Takeshi, Nakamura Hidenori, Suzuki Takuji. A retrospective comparison between digital to conventional drainage systems for secondary spontaneous pneumothorax related to diffuse interstitial lung disease.. The clinical respiratory journal. 2023. DOI: 10.1111/crj.13654.