DOI 10.1016/j.pulmoe.2023.04.003
Diagnostic yield and safety of transbronchial lung cryobiopsy for diffuse parenchymal lung diseases diagnosis: Comparison between 1.7-mm and 1.9-mm probes.
Аннотация
Purpose of the research: transbronchial lung cryobiopsy has been recently accepted as a valid and less invasive alternative to surgical lung biopsy. The purpose of this randomized controlled study was to evaluate, for the first time, the quality and safety of biopsy specimens obtained by using the new disposable 1.7-mm cryoprobe compared with the standard re-usable 1.9 mm cryoprobe in the diagnosis of diffuse parenchymal lung diseases.
Methods
60 consecutive patients were prospectively enrolled and randomly assigned to two different groups: 1.9 mm (group A) and 1.7 mm (group B); primary endpoints were pathological and multidisciplinary diagnostic yield, sample size and complication rate. Principal results: the pathological diagnostic yield of cryobiopsy was 100% in group A and 93.3% in group B (p = 0.718); cryobiopsy median diameter was 6.8 mm in group A and 6.7 mm in group B (p = 0,5241). Pneumothorax occurred in 9 patients in group A and 10 in group B (p = 0.951); mild-to-moderate bleeding in 7 cases and 9 cases in group A and B respectively (p = 0.559). No death or severe adverse events were observed.
Conclusions
there was no statistically significant difference between the two groups, regarding diagnostic yield, adverse events and sampling adequacy.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.