MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5152/tjar.2021.1427

Медицинская библиотека · Turkish journal of anaesthesiology and reanimation · 2022

What About Compressing the Oesophagus with an Ultrasound Probe for a Modified Sellick Maneuver?

Bermede Onat, Meço Başak Ceyda, Baytaş Volkan, Dilken Olcay, Yıldırım Güçlü Çiğdem, Karadağ Erkoç Süheyla, Alanoğlu Zekeriyya, Alkış Neslihan

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Debates continue about the cricoid pressure, which has been used for many years to prevent gastric aspiration during intubation. Using ultrasound, the effects of this maneuver and alternatives like paralaryngeal pressure are revealed. The aim of this observational study was to determine the effect of paralaryngeal pressure with an ultrasound probe on the esophageal diameter in patients with different body mass indexes and neck circumferences.

METHODS

After measuring the neck circumference at the level of the cricoid cartilage, the esophagus was visualized by ultrasonography. Compression was applied medially at a 45° angle toward the vertebral column by the ultrasound probe and esophageal anteroposterior outer diameters were measured. Correlations between body mass index, neck circumference, esophageal diameter, and esophageal diameter change ratio were evaluated with Pearson's r value.

RESULTS

One hundred ten volunteers (52 women and 58 men) with mean age 33.7 ± 8.02 years and mean body mass index 25.6 ± 4.65 kg m-2 were recruited. The esophagus was located 78.18% partially to the left, 4.54% completely to the left, 1.81% to the right of the cricoid ring. In 15.45%, esophagus could not be displayed. The mean diameter of the esophagus was 7.6 ± 1.1 mm before pressure and 5.6 ± 0.09 mm after pressure (P < .001). There was no significant correlation between diameter change percentage and body mass index (r=-0.22; P > .05). However, weak correlation was found between diameter change percentage and neck circumference (r=-0.33; P=.016).

CONCLUSIONS

Paralaryngeal pressure with an ultrasound probe has the potential to occlude the esophagus and may be effective in all patient groups.

Для цитирования: Bermede Onat, Meço Başak Ceyda, Baytaş Volkan, Dilken Olcay, Yıldırım Güçlü Çiğdem, Karadağ Erkoç Süheyla, Alanoğlu Zekeriyya, Alkış Neslihan. What About Compressing the Oesophagus with an Ultrasound Probe for a Modified Sellick Maneuver?. Turkish journal of anaesthesiology and reanimation. 2022. DOI: 10.5152/tjar.2021.1427.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.