MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jocn.2012.02.001

Медицинская библиотека · Journal of clinical neuroscience : official journal of the Neurosurgical Society of Australasia · 2012

The effect of formal training on the clinical utility of transcranial Doppler ultrasound monitoring in patients with aneurysmal subarachnoid haemorrhage.

Bhuiyan M Rasin, Deb Smita, Mitchell Ruth A, Teddy Peter J, Drummond Katharine J

СтатьяПеревод пока не подготовлен

Аннотация

We have previously shown that the clinical utility of transcranial Doppler (TCD) ultrasound monitoring for vasospasm in patients with aneurysmal subarachnoid haemorrhage, as performed by untrained operators in a busy neurosurgical unit, is questionable, despite the recommendations for its use in the literature. We determined if formal training improved the utility of TCD. Twelve untrained operators and one trained operator performed a total of 206 TCD examinations. There was poor agreement of results between trained and untrained operators. For the left middle cerebral artery (MCA), right MCA, left anterior cerebral artery (ACA) and right ACA, the blood flow velocities (BFV) recorded by the trained operator were greater than those recorded by the untrained operators by a mean (95% confidence interval) of 27.7 (25.0-30.4), 24.3 (21.4-27.1), 28.2 (25.6-30.9) and 28.1 (24.9-31.1) cm/s, respectively (p<0.001 for all vessels). Greater sensitivity was observed in TCD measurements from the trained operator (100%) compared to untrained operators (40%). To improve the utility of TCD, operators should be provided with training or a professional sonographer employed.

Для цитирования: Bhuiyan M Rasin, Deb Smita, Mitchell Ruth A, Teddy Peter J, Drummond Katharine J. The effect of formal training on the clinical utility of transcranial Doppler ultrasound monitoring in patients with aneurysmal subarachnoid haemorrhage.. Journal of clinical neuroscience : official journal of the Neurosurgical Society of Australasia. 2012. DOI: 10.1016/j.jocn.2012.02.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.