MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/17534666241249150

Медицинская библиотека · Therapeutic advances in respiratory disease · 2024

Diagnostic yield using electromagnetic navigation bronchoscopy for peripheral pulmonary nodules <2 cm.

Chen Jun-Ying, Yang Han, Lin Xiao-Dan, Yang Hong, Wen Jing, Liu Qian-Wen, Zhang Lan-Jun, Lin Peng, Fu Jian-Hua, Leng Chang-Sen, Yi Rong, Luo Kong-Jia

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Although electromagnetic navigation bronchoscopy (ENB) is highly sensitive in the diagnosis of peripheral pulmonary nodules (PPNs), its diagnostic yield for subgroups of smaller PPNs is under evaluation.

OBJECTIVES

Diagnostic yield evaluation of biopsy using ENB for PPNs <2 cm.

DESIGN

The diagnostic yield, sensitivity, specificity, positive predictive value, and negative predictive value of the ENB-mediated biopsy for PPNs were evaluated.

METHODS

Patients who had PPNs with diameters <2 cm and underwent ENB-mediated biopsy between May 2015 and February 2020 were consecutively enrolled. The final diagnosis was made via pathological examination after surgery.

RESULTS

A total of 82 lesions from 65 patients were analyzed. The median tumor size was 11 mm. All lesions were subjected to ENB-mediated biopsy, of which 29 and 53 were classified as malignant and benign, respectively. Subsequent segmentectomy, lobectomy, or wedge resection, following pathological examinations were performed on 64 nodules from 57 patients. The overall sensitivity, specificity, positive predictive value, and negative predictive value for nodules <2 cm were 53.3%, 91.7%, 92.3%, and 51.2%, respectively. The receiver operating curve showed an area under the curve of 0.721 (p < 0.001). Additionally, the sensitivity, specificity, positive predictive value, and negative predictive value were 62.5%, 100%, 100%, and 42.9%, respectively, for nodules with diameters equal to or larger than 1 cm; and 30.8%, 86.7%, 66.7%, and 59.1%, respectively, for nodules less than 1 cm. In the subgroup analysis, neither the lobar location nor the distance of the PPNs to the pleura affected the accuracy of the ENB diagnosis. However, the spiculated sign had a negative impact on the accuracy of the ENB biopsy (p = 0.010).

CONCLUSION

ENB has good specificity and positive predictive value for diagnosing PPNs <2 cm; however, the spiculated sign may negatively affect ENB diagnostic accuracy. In addition, the diagnostic reliability may only be limited to PPNs equal to or larger than 1 cm.

Для цитирования: Chen Jun-Ying, Yang Han, Lin Xiao-Dan, Yang Hong, Wen Jing, Liu Qian-Wen, Zhang Lan-Jun, Lin Peng, Fu Jian-Hua, Leng Chang-Sen, Yi Rong, Luo Kong-Jia. Diagnostic yield using electromagnetic navigation bronchoscopy for peripheral pulmonary nodules <2 cm.. Therapeutic advances in respiratory disease. 2024. DOI: 10.1177/17534666241249150.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.