Journal of cataract and refractive surgery · 2023
Ptosis effects on intraocular lens power calculation.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Aydemir Emre, Aksoy Aydemir Gozde
Аннотация
PURPOSE: To evaluate quantitatively ocular biometric parameters and intraocular lens (IOL) power measurements after ptosis surgery.
SETTING: Adiyaman University Hospital, Adiyaman, Turkey.
DESIGN: Comparative prospective clinical study.
METHODS: This study comprised involutional ptosis patients divided into droopy eyelid severity groups: Group 1: >4 mm, Group 2: 3 to 4 mm, and Group 3: 1 to 2 mm. The patients underwent anterior levator resection, and preoperative and postoperative biometry measurements at 3 months postoperatively were obtained.
RESULTS: The Group 1 sample size was 19, Group 2 was 22, and Group 3 was 16. The mean flattest keratometry (K 1 ), steepest keratometry (K 2 ), and mean keratometry (K m ) values significantly decreased at 3 months postoperatively in Group 1 ( P < .001 for all). The mean K 1 , K 2 , and K m values nonsignificantly decreased at 3 months postoperatively in Groups 2 and 3 ( P > .05 for all). The mean corneal astigmatism magnitude decreased at 3 months postoperatively in Group 1 ( P < .01), Group 2 ( P = .186), and Group 3 ( P = .952). The mean recommended IOL powers targeting emmetropia increased postoperatively in Group 1 and were similar preoperatively and postoperatively in Groups 2 and 3. In Group 1, the mean changes after ptosis surgery by the formula were 0.47 diopters (D) for SRK/T, 0.52 D for Hoffer Q, 0.55 D for Haigis, 0.50 D for Barrett Universal II, and 0.55 D for Holladay 2.
CONCLUSIONS: Ptosis >4 mm significantly affects corneal curvature values and IOL power calculations when cataract surgery is planned. Surgeons might consider altering their lens power choice accordingly if cataract surgery is to be sequentially followed by ptosis repair.
SETTING: Adiyaman University Hospital, Adiyaman, Turkey.
DESIGN: Comparative prospective clinical study.
METHODS: This study comprised involutional ptosis patients divided into droopy eyelid severity groups: Group 1: >4 mm, Group 2: 3 to 4 mm, and Group 3: 1 to 2 mm. The patients underwent anterior levator resection, and preoperative and postoperative biometry measurements at 3 months postoperatively were obtained.
RESULTS: The Group 1 sample size was 19, Group 2 was 22, and Group 3 was 16. The mean flattest keratometry (K 1 ), steepest keratometry (K 2 ), and mean keratometry (K m ) values significantly decreased at 3 months postoperatively in Group 1 ( P < .001 for all). The mean K 1 , K 2 , and K m values nonsignificantly decreased at 3 months postoperatively in Groups 2 and 3 ( P > .05 for all). The mean corneal astigmatism magnitude decreased at 3 months postoperatively in Group 1 ( P < .01), Group 2 ( P = .186), and Group 3 ( P = .952). The mean recommended IOL powers targeting emmetropia increased postoperatively in Group 1 and were similar preoperatively and postoperatively in Groups 2 and 3. In Group 1, the mean changes after ptosis surgery by the formula were 0.47 diopters (D) for SRK/T, 0.52 D for Hoffer Q, 0.55 D for Haigis, 0.50 D for Barrett Universal II, and 0.55 D for Holladay 2.
CONCLUSIONS: Ptosis >4 mm significantly affects corneal curvature values and IOL power calculations when cataract surgery is planned. Surgeons might consider altering their lens power choice accordingly if cataract surgery is to be sequentially followed by ptosis repair.