m+Medelevator.RU
← Поиск публикаций
Journal of refractive surgery (Thorofare, N.J. : 1995) · 2022

Comparison of the Functional Optical Zone in Eyes With High Myopia With High Astigmatism After SMILE and FS-LASIK.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Liu Shengtao, Zhang Xiaoxue, Niu Lingling, Yu Zhiqiang, Zhou Xingtao, Zhao Jing

Аннотация

PURPOSE: To compare the functional optical zone (FOZ) in eyes with high myopia with high astigmatism after small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK).

METHODS: In total, 45 eyes of 45 patients with high myopia with astigmatism greater than 2.00 diopters (D) who underwent SMILE or FS-LASIK were enrolled. The FOZ, optical zone decentration, and corneal aberrations were analyzed using Scheimpflug imaging. These values were then compared between the two groups 6 months postoperatively.

RESULTS: No postoperative complications were observed during follow-up. The mean FOZ diameter was 5.03 ± 0.31 mm for the FS-LASIK group and 5.24 ± 0.27 mm for the SMILE group (P = .007), corresponding to reductions of 1.18 ± 0.23 and 1.01 ± 0.21 mm, respectively, compared with the programmed optical zone (POZ) (P = .013). A significant difference was noted in the FOZ on the short axis between the two groups (P = .002), whereas no significant difference was observed on the long axis (P = .088). The FOZ area in the FS-LASIK and SMILE groups was 65.39 ± 6.14% and 70.09 ± 5.46% of the POZ area, respectively (P = .010). There was no significant difference in decentration between the two groups (0.29 ± 0.13 mm for the FS-LASIK group vs 0.30 ± 0.13 mm for the SMILE group, P = .798). A significant increase in spherical aberration was observed in the FS-LASIK group (P < .001). However, the induction of vertical coma was higher in the SMILE group than in the FS-LASIK group (P = .002).

CONCLUSIONS: Eyes with high myopia with high astigmatism following SMILE achieved a larger FOZ and less spherical aberration but a larger vertical coma introduction than following FS-LASIK. [J Refract Surg. 2022;38(9):595-601.].

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты