MedElevator Войти в исследования
← Поиск публикаций

DOI 10.17116/oftalma202213804174

Медицинская библиотека · Vestnik oftalmologii · 2022

[Long-term clinical and functional outcomes of high myopia correction by femtosecond laser-assisted implantation of an intrastromal ring].

Kulikova I L, Pozdeyeva N A, Terentieva A E, Sinitsyn M V

СтатьяОригинал на русском

Аннотация

OBJECTIVE

To analyze remote clinical and functional outcomes of correcting high myopia in patients with thin cornea by the method of femtosecond laser-assisted implantation of intracorneal implant MyoRing.

MATERIAL AND

METHODS

The study included 22 patients (22 eyes; the mean age of study patients was 30.2±5.37 years). Mean spherical equivalent (SE) of refraction was -11.52±1.96 D, cylindrical component (cyl) of refraction was -2.04±1.64 D, minimal pachymetry index in the center was 491.6±20 µm, corneal hysteresis (CH) amounted to 8.6±1.19 mm Hg. The average pupil diameter in mesopic conditions was 5.6±0.23 mm. All patients had a history of mild amblyopia. The follow-up period lasted 2 years.

RESULTS

Two years after the surgery uncorrected visual acuity was 0.6±1.22, corrected visual acuity 0.7±0.20. Mean spherical equivalent (SE) of refraction was 0.61±1.43 D, cylindrical component of refraction was -0.13±0.5 D. Predictability of SE within ±0.5 D was recorded in 84% of cases, ±1.0 - also in 84% of cases. Index of safety was 1.16, index of efficacy - 1.0. CH was 9.5±0.03 mm Hg. Mean pachymetry at the center did not change statistically significantly after the surgery in comparison to the initial data (p=1.00).

CONCLUSION

MyoRing implantation is an effective and safe method, which ensures correction of the spherical component of refraction, as well as correction of astigmatism, improvement of biomechanical properties of the cornea, and an increase in corneal hysteresis (p=0.01).

Для цитирования: Kulikova I L, Pozdeyeva N A, Terentieva A E, Sinitsyn M V. [Long-term clinical and functional outcomes of high myopia correction by femtosecond laser-assisted implantation of an intrastromal ring].. Vestnik oftalmologii. 2022. DOI: 10.17116/oftalma202213804174.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.