Saving of Time Using a Software-Based versus a Manual Workflow for Toric Intraocular Lens Calculation and Implantation.

Brunner Barbara S, Luft Nikolaus, Priglinger Siegfried G, Shajari Mehdi, Mayer Wolfgang J, Kassumeh Stefan

СтатьяПеревод пока не подготовлен

Аннотация

Background

To determine whether there is a significant saving of time when using a digital cataract workflow for digital data transfer compared to a manual approach of biometry assessment, data export, intraocular lens calculation, and surgery time.

Methods

In total, 48 eyes of 24 patients were divided into two groups: 24 eyes were evaluated using a manual approach, whereas another 24 eyes underwent a full digital lens surgery workflow. The primary variables for comparison between both groups were the overall time as well as several time steps starting at optical biometry acquisition until the end of the surgical lens implantation. Other outcomes, such as toric intraocular lens misalignment, reduction of cylinder, surgically induced astigmatism, prediction error, and distance visual acuity were measured.

Results

Overall, the total diagnostic and surgical time was reduced from 1364.1 ± 202.6 s in the manual group to 1125.8 ± 183.2 s in the digital group (p < 0.001). The complete time of surgery declined from 756.5 ± 82.3 s to 667.3 ± 56.3 (p < 0.0005). Compared to the manual approach of biometric data export and intraocular lens calculation (76.7 ± 12.3 s) as well as the manual export of the reference image to a portable external storage device (26.8 ± 5.5 s), a highly significant saving of time was achieved (p < 0.0001).

Conclusions

Using a software-based digital approach to toric intraocular lens implantation is convenient, more efficient, and thus more economical than a manual workflow in surgery practice.

Для цитирования: Brunner Barbara S, Luft Nikolaus, Priglinger Siegfried G, Shajari Mehdi, Mayer Wolfgang J, Kassumeh Stefan. Saving of Time Using a Software-Based versus a Manual Workflow for Toric Intraocular Lens Calculation and Implantation.. Journal of clinical medicine. 2022. DOI: 10.3390/jcm11102907.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.