m+Medelevator.RU
← Поиск публикаций
BMC ophthalmology · 2022

Correction of pre-existing astigmatism with phacoemulsification using toric intraocular lens versus spherical intraocular lens and wave front guided surface ablation.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

El-Shehawy Ahmed, El-Massry Ahmed, El-Shorbagy Mohamed Sameh, Atef Mohamed, Sabry Moataz

Аннотация

BACKGROUND: This study aimed to evaluate toric intraocular lens to correct of pre-existing astigmatism at the time of phacoemulsification compared to using of spherical intraocular lens followed by wavefront guided surface ablation.

RESULTS: The patients were classified into three groups: Group A with 20 eyes of 19 patients having phacoemulsification with spherical intraocular lens only as a control group, group B with 20 eyes of 14 patients had phacoemulsification with toric intraocular lens and group C with 20 eyes of 16 patients had phacoemulsification with spherical intraocular lens and wavefront guided PRK three months later. Comparison pre-operative data for all groups showed no statistically significant difference regarding UCVA, BCVA, MRSE, and refractive astigmatism (P>0.05). Post operatively, there was a statistically significant difference for UCVA, BCVA, MRSE, and refractive astigmatism for group A compared to group B (P<0.05) and group A compared to group C but there was no statistically significant difference for group B compared to C regarding all these parameters (P>0.05).

CONCLUSION: In this study, we found similar effects for both techniques in astigmatism corrected groups while both differed from the control group that was not corrected. Correcting preexisting astigmatism during cataract surgery should be in mind in every case to improve visual outcomes. Longer period of follow up are required to evaluate stability of these techniques and possibility of regression.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты