MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7754/clin.lab.2020.200714

Медицинская библиотека · Clinical laboratory · 2021

Reference Interval for Korean Serum Folate Assay Traceable to the WHO International Standard.

Choi Rihwa, Oh Youngju, Park Mi-Jung, Lee Sang Gon, Lee Eun Hee

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Little is known about the reference interval of serum folate concentration if using recently re-standardized assays traceable to the World Health Organization (WHO) international standard reference 03/178 in a Korean population. This study aimed to investigate serum folate levels in Korean subjects without macrocytic anemia or increased homocysteine, for the assessment of folate deficiency.

METHODS

We retrospectively reviewed data from Korean adults whose hemoglobin, mean corpuscular volume, and serum total homocysteine values were within reference limits.

RESULTS

The median (interquartile range) serum folate level was 7.8 (5.4 - 12.6) ng/mL in men and 10.2 (6.9 - 15.6) ng/mL in women. The reference interval for serum folate (2.5th and 97.5th percentiles) ranged from 2.9 to 38.0 ng/ mL. From among 723 Korean adults, the lower limit of reference intervals of serum folate for folate deficiency, defined as the 2.5th percentile, was 2.9 ng/mL. The prevalence of folate deficiency was higher in men (6.5%) than in women (1.2%, p < 0.05) when a cutoff value of 3.0 ng/mL was applied. Using the cutoff value of 4 ng/mL for folate deficiency, which is in accordance with the instructions from the manufacturer of the new assay and the WHO 2012 guideline for homocysteine as a metabolic indicator before assay standardization, about 5% of subjects were reclassified as folate deficient.

CONCLUSIONS

Our study suggests that any change of reference limits using a re-standardized assay needs to be verified in clinical laboratories.

Для цитирования: Choi Rihwa, Oh Youngju, Park Mi-Jung, Lee Sang Gon, Lee Eun Hee. Reference Interval for Korean Serum Folate Assay Traceable to the WHO International Standard.. Clinical laboratory. 2021. DOI: 10.7754/clin.lab.2020.200714.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.