Медицинская библиотека · Journal of cardiovascular medicine (Hagerstown, Md.) · 2018

Carotid Doppler sonography: additional tool to assess hemodynamic improvement after transcatheter aortic valve implantation.

Cammalleri Valeria, Romeo Francesco, Marchei Massimo, Anceschi Andrea, Massaro Gianluca, Muscoli Saverio, De Persis Francesca, Macrini Massimiliano, Ussia Gian P

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The aim of our study was to assess the arterial cerebral blood flow variations in patients with aortic valve stenosis, immediately after the transcatheter aortic valve implantation (TAVI).

METHODS

The study population includes 62 consecutive patients who underwent TAVI for aortic valve stenosis (95%) and sugical bioprosthesis degeneration (5%). Carotid Doppler examination was performed recording blood flow, systolic peak velocity, time average mean velocity and mean acceleration time at baseline, after balloon aortic valvuloplasty, and within 10 min after the device release.

RESULTS

A significant improvement of blood flow was recorded at the end of the procedure (from 315.05 ± 141.72 to 538.67 ± 277.46 ml/min; P < 0.00001). The systolic peak velocity and the time average mean velocity increased from 52.27 ± 14.29 to 78.89 ± 20.48 cm/s (P < 0.00001) and from 12.24 ± 4.74 to 21.21 ± 9 cm/s (P < 0.00001), respectively. Consensually, the mean acceleration time decreased from 0.22 ± 0.02 to 0.03 ± 0.02 s (P < 0.00001) after the procedure.

CONCLUSION

Monitoring of Doppler measurements may be a useful and noninvasive method to assess acutely the improvement of hemodynamic flow after TAVI, specifically for the cerebral district.

Для цитирования: Cammalleri Valeria, Romeo Francesco, Marchei Massimo, Anceschi Andrea, Massaro Gianluca, Muscoli Saverio, De Persis Francesca, Macrini Massimiliano, Ussia Gian P. Carotid Doppler sonography: additional tool to assess hemodynamic improvement after transcatheter aortic valve implantation.. Journal of cardiovascular medicine (Hagerstown, Md.). 2018. DOI: 10.2459/jcm.0000000000000622.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.