MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jon.12489

Медицинская библиотека · Journal of neuroimaging : official journal of the American Society of Neuroimaging · 2017

Decreased Signal Intensity Ratio on MRA Reflects Misery Perfusion on SPECT in Patients with Intracranial Stenosis.

Miura Masatomo, Nakajima Makoto, Fujimoto Akiko, Shiraishi Shinya, Liebeskind David S, Ando Yukio

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: Acetazolamide reactivity on 123 I-IMP SPECT is used to detect misery perfusion due to intracranial atherosclerosis. Noninvasive fractional flow assessed by signal intensity ratio (SIR) on time of flight-magnetic resonance angiography (TOF-MRA) might offer a feasible alternative to identify high-risk intracranial stenosis.

METHODS

Data from consecutive patients with unilateral middle cerebral artery (MCA) stenosis who underwent both TOF-MRA and acetazolamide reactivity on 123 I-IMP SPECT were retrospectively analyzed. Signal intensity was measured in the background and on the MCA proximal and distal to the stenotic lesion on TOF-MRA. Mean cerebral blood flow (CBF) at rest and cerebrovascular reactivity were measured in the target MCA territory. CBF patterns of the MCA were divided into three groups (Powers' stage 0-II).

RESULTS

A total of 56 sets of diagnostic imaging in 33 patients were assessed. Four CBF patterns were stage II in four MCA territories, stage I in 31, and stage 0 in 21. Median SIR of the MCA was .53 (interquartile range .46-.69) for stage II, .78 (.63-.90) for stage I, and .91 (.85-.95) for stage 0. The optimal cutoff for SIR obtained from receiver operating characteristic curve analysis to predict stage II was < .56.

CONCLUSIONS

In patients with unilateral MCA stenosis, decreased SIR was correlated with misery perfusion, providing a simpler, widely available predictor of high-risk intracranial stenosis.

Для цитирования: Miura Masatomo, Nakajima Makoto, Fujimoto Akiko, Shiraishi Shinya, Liebeskind David S, Ando Yukio. Decreased Signal Intensity Ratio on MRA Reflects Misery Perfusion on SPECT in Patients with Intracranial Stenosis.. Journal of neuroimaging : official journal of the American Society of Neuroimaging. 2017. DOI: 10.1111/jon.12489.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.