European neurology · 2017
Anterior Borderzone Angle for Hemodynamic Collateral Metric in Patients with Symptomatic Middle Cerebral Artery Stenosis.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Li Yongkun, Xiong Yunyun, Cai Qiankun, Liu Dezhi, Dai Qiliang, Liu Wenhua, Huang Zhixin, Sun Wen, Liebeskind David S, Wang Yinzhou, Liu Xinfeng
Аннотация
BACKGROUND AND AIMS: We aimed to introduce a parameter of anterior borderzone angle (ABZA) to quantitatively evaluate the ACA-MCA leptomeningeal collaterals for middle cerebral artery stenosis (MCAS).
METHODS: Two hundred seventy-five patients with 50-100% MCAS and 100 controls were included. The 95% reference range of ABZA was obtained from the controls. ABZAtrans was defined as "ABZA/the 95% upper limit." Relationships between ABZA and MCAS, -ABZAtrans and the TICI grade, the American Society of Interventional and Therapeutic Neuroradiology/Society of Interventional Radiology (ASITN/SIR) collateral grade were analyzed. An ABZA grade model for the ACA leptomeningeal collaterals was tentatively developed.
RESULTS: The 95% reference range of ABZA was 0.0º-23.0º. ABZA was significantly associated with MCAS by a function of the fourth power (R2 = 0.723, p < 0.001), and could predict hemodynamic MCAS (≥70%) with an AUC of 0.928 (95% CI 0.903-0.953). ABZAtrans was negatively correlated with the TICI grade (rho = -0.752, p < 0.001) and positively with the ASITN/SIR grade (rho = 0.921, p < 0.001). The ABZA grade was created by rounding -ABZAtrans to a nearest integer, and was closely associated with the ASITN/SIR grade (rho = 0.894, p < 0.001).
CONCLUSIONS: ABZA can be used as a hemodynamic parameter to quantitatively evaluate ACA leptomeningeal collaterals.
METHODS: Two hundred seventy-five patients with 50-100% MCAS and 100 controls were included. The 95% reference range of ABZA was obtained from the controls. ABZAtrans was defined as "ABZA/the 95% upper limit." Relationships between ABZA and MCAS, -ABZAtrans and the TICI grade, the American Society of Interventional and Therapeutic Neuroradiology/Society of Interventional Radiology (ASITN/SIR) collateral grade were analyzed. An ABZA grade model for the ACA leptomeningeal collaterals was tentatively developed.
RESULTS: The 95% reference range of ABZA was 0.0º-23.0º. ABZA was significantly associated with MCAS by a function of the fourth power (R2 = 0.723, p < 0.001), and could predict hemodynamic MCAS (≥70%) with an AUC of 0.928 (95% CI 0.903-0.953). ABZAtrans was negatively correlated with the TICI grade (rho = -0.752, p < 0.001) and positively with the ASITN/SIR grade (rho = 0.921, p < 0.001). The ABZA grade was created by rounding -ABZAtrans to a nearest integer, and was closely associated with the ASITN/SIR grade (rho = 0.894, p < 0.001).
CONCLUSIONS: ABZA can be used as a hemodynamic parameter to quantitatively evaluate ACA leptomeningeal collaterals.