MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jaci.2018.06.010

Медицинская библиотека · The Journal of allergy and clinical immunology · 2018

NAVIGATE II: Randomized, double-blind trial of the exhalation delivery system with fluticasone for nasal polyposis.

Leopold Donald A, Elkayam David, Messina John C, Kosik-Gonzalez Colette, Djupesland Per G, Mahmoud Ramy A

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Chronic rhinosinusitis is common and sometimes complicated by nasal polyps (NPs). Corticosteroid nasal sprays are often unsatisfactory because they are ineffective at delivering medication to high/deep sites of inflammation.

OBJECTIVE

We sought to assess whether an exhalation delivery system with fluticasone (EDS-FLU) capable of high/deep drug deposition improves outcomes.

METHODS

Patients (n = 323) 18 years and older with moderate-to-severe congestion and NPs were randomized to twice-daily EDS-FLU (93, 186, or 372 μg) or exhalation delivery system (EDS)-placebo for 24 weeks (16 double-blind plus 8 open-label when all received 372 μg). Coprimary end points were change in nasal congestion/obstruction at 4 weeks and summed bilateral polyp grade at 16 weeks. Secondary end points included symptoms, polyp elimination, and functioning.

RESULTS

EDS-FLU was superior on both coprimary end points (P < .001 vs EDS-placebo, all doses). Mean polyp grade improved continuously through week 24 (P < .009, all comparisons), with polyps eliminated on at least 1 side in approximately 25% of patients at week 24 versus 8.7% with EDS-placebo (P ≤ .014, all comparisons). Sino-Nasal Outcomes Test scores also improved significantly versus those in patients receiving EDS-placebo (-21.1 to -21.4 vs -11.7 at week 16, P < .05 all doses). At the end of the double-blind period, EDS-FLU (all doses) significantly improved all 4 defining disease symptoms. In most patients (68%), those receiving EDS-FLU reported "much" or "very much" improvement. The number of patients eligible for surgery decreased by 62%-67%. The safety profile was similar to that reported in prior trials evaluating conventional corticosteroid nasal sprays in comparable populations.

CONCLUSION

EDS-FLU produces clinically and statistically significant improvement in all 4 diagnostically defining disease symptoms, polyp grade, and quality of life in patients with chronic rhinosinusitis with NPs.

Для цитирования: Leopold Donald A, Elkayam David, Messina John C, Kosik-Gonzalez Colette, Djupesland Per G, Mahmoud Ramy A. NAVIGATE II: Randomized, double-blind trial of the exhalation delivery system with fluticasone for nasal polyposis.. The Journal of allergy and clinical immunology. 2018. DOI: 10.1016/j.jaci.2018.06.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.