m+Medelevator.RU
← Поиск публикаций
Critical care (London, England) · 2017

Determinants of the calibration of SAPS II and SAPS 3 mortality scores in intensive care: a European multicenter study.

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Poncet Antoine, Perneger Thomas V, Merlani Paolo, Capuzzo Maurizia, Combescure Christophe

Аннотация

BACKGROUND: The aim of the Simplified Acute Physiology Score (SAPS) II and SAPS 3 is to predict the mortality of patients admitted to intensive care units (ICUs). Previous studies have suggested that the calibration of these scores may vary across countries, centers, and/or characteristics of patients. In the present study, we aimed to assess determinants of the calibration of these scores.

METHODS: We assessed the calibration of the SAPS II and SAPS 3 scores among 5266 patients admitted to ICUs during a 4-week period at 120 centers in 17 European countries. We obtained calibration curves, Brier scores, and standardized mortality ratios. Points attributed to SAPS items were reevaluated and compared with those of the original scores. Finally, we tested associations between the calibration and center characteristics.

RESULTS: The mortality was overestimated by both scores: The standardized mortality ratios were 0.75 (95% CI 0.71-0.79) for the SAPS II score and 0.91 (95% CI 0.86-0.96) for the SAPS 3 score. This overestimation was partially explained by changes in associations between some items of the scores and mortality, especially the heart rate, Glasgow Coma Scale score, and diagnosis of AIDS for SAPS II. The calibration of both scores was better in countries with low health expenditures. The between-center variability in calibration curves was much greater than expected by chance.

CONCLUSIONS: Both scores overestimate current mortality among European ICU patients. The magnitude of the miscalibration of SAPS II and SAPS 3 scores depends not only on patient characteristics but also on center characteristics. Furthermore, much between-center variability in calibration remains unexplained by these factors.

TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT01422070 . Registered 19 August 2011.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты