Zhang Rongli, Situ Zhiquan, Cheng Zhangbo, Luo Yande, Qiu Xiongfeng, He Xin, Yuan Xinchen, Zhou Zijie, Rong Zhaowei, Lin Yunhai, Li Qi, Sun Bin, Wu Huizhong, Jiang Huilin, Zhou Wu, Xie Guoxi

Аннотация

Aortic dissection (AD) is a life-threatening cardiovascular emergency. Non-contrast-enhanced computed tomography (NCE-CT) could provide timely AD screening with fewer contraindications compared to CE-CT imaging. However, NCE-CT examinations lack distinctive imaging characteristics of AD, leading to high rates of missed diagnoses and misdiagnoses, and increased radiologist workload. In this paper, we propose a novel end-to-end multi-task framework for automated aortic segmentation and AD detection using NCE-CT images. The framework comprises three main components: a deformable feature extractor enhancing aorta tubular-feature attention, an adaptive geometric information extraction module to optimize feature sharing between segmentation and classification tasks via the transformer cross-attention mechanism, and a knowledge distillation module transferring diagnostic information from the CE-CT-based teacher model to the NCE-CT-based student model. Multi-center tests across 3 internal and 2 external centers demonstrated that our model outperformed existing methods both for segmenting the aorta and detecting AD. Specifically, for segmenting the aorta, our framework achieved dice of 0.928 and 0.909, Jaccard index (JI) of 0.867 and 0.858, mean intersection over union (MIoU) of 0.932 and 0.913, and frequency-weighted IoU (FWIoU) of 0.995 and 0.994, in internal and external testing datasets, respectively. For identifying AD patients from non-AD patients, our framework achieved accuracies of 0.911 and 0.840, sensitivities of 0.925 and 0.888, andF1-scores of 0.922 and 0.836, in internal and external testing datasets, respectively. Ablation experiment demonstrates the effectiveness of each module. The proposed model may serve as an effective diagnostic assistant for radiologists, acting as a 'second pair of eyes' to assist in AD screening using NCE-CT images.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты