MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/md.0000000000000677

Медицинская библиотека · Medicine · 2015

The effect of corneal irregularity on astigmatism measurement by automated versus ray tracing keratometry.

Roh Hyun Cheol, Chuck Roy S, Lee Jimmy K, Park Choul Yong

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The aim of this study was to compare the effect of corneal irregularity on astigmatism assessment using automated keratometry (AK) (IOLMaster) versus ray tracing keratometry (Pentacam). This is an observational case series approved by the institutional review board of Dongguk University Hospital, Goyang, South Korea. A total of 207 eyes of 207 cataract patients were included. Preoperative corneal astigmatism was measured by both IOLMaster and Pentacam. Corneal irregularity index (IR) was calculated in Fourier analysis map of Pentacam. AK by IOLMaster and total corneal refractive power (TCRP, 3 mm and 4 mm zone analysis with pupil centered) by Pentacam were selected and the difference between the 2 measurements (delta Δ) was calculated using vector analysis. Ocular residual astigmatism (ORA) after cataract surgery was calculated by subtracting 6-month postoperative refractive astigmatism (RA) measurements from corresponding preoperative values (AK, TCRP3, and TCRP4). The mean irregularity index measured was 0.042 ± 0.019 mm (mean ± standard deviation) and was positively correlated with age and magnitude of corneal astigmatism (P < 0.001 and P < 0.05). The difference (Δ) between TCRPs and AK (ΔTCRPs-AK) was 0.43 ± 0.37 (TCRP3) and 0.39 ± 0.35 (TCRP4) diopters. Linear regression analysis revealed that age (P < 0.001), IR (P < 0.001), and AK (P < 0.001) were positively correlated with ΔTCRPs-AK. In highly irregular corneas (IR over 0.77 diopters: mean + 2 standard deviation), postoperative ORAs calculated using TCRPs were significantly lower than ORAs calculated using AK. Corneal irregularities significantly impact astigmatism assessment by IOLMaster (AK) and Pentacam (TCRPs). Compared with AK, TCRPs were more accurate in predicting postoperative residual astigmatism in highly irregular corneas.

Для цитирования: Roh Hyun Cheol, Chuck Roy S, Lee Jimmy K, Park Choul Yong. The effect of corneal irregularity on astigmatism measurement by automated versus ray tracing keratometry.. Medicine. 2015. DOI: 10.1097/md.0000000000000677.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.