Evaluation of eyedrop administration by inexperienced patients after cataract surgery.

An Jella Angela, Kasner Oscar, Samek Deborah Anne, Lévesque Valérie

Оценочное исследованиеСтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate efficacy and safety of eyedrop administration after cataract surgery and to identify predictors of better technique in patients without previous eyedrop experience.

SETTING

Department of Ophthalmology, McGill University, Jewish General Hospital, Montreal, Quebec, Canada.

DESIGN

Prospective cross-sectional study.

METHODS

Eyedrop-naïve postoperative cataract patients were consecutively recruited the day after cataract surgery. Data were collected using a standardized self-reporting questionnaire and a chart review and by videotaping patients administering the drops in the operated eye. Two independent observers objectively evaluated the instillation technique. Predictors were assessed using odds ratios (ORs) from a logistic regression model.

RESULTS

The study enrolled 54 patients. Subjectively, 17 patients (31%) reported difficulty instilling the eyedrops. Sixty-nine percent reported always washing their hands before using the drops, 42% believed that they never missed their eye when instilling drops, and 58.3% believed they never touched their eye with the bottle tip. Objectively, 50 patients (92.6%) showed an improper administration technique, including missing the eye (31.5%), instilling an incorrect amount of drops (64.0%), contaminating the bottle tip (57.4%), or failing to wash hands before drop instillation (78.0%). A better performance score was significantly associated with having received instructions on how to use drops (OR, 11.99; P=.011).

CONCLUSIONS

Postoperative cataract patients inexperienced with eyedrop use showed a poor instillation technique by failing to wash hands, contaminating bottle tips, missing the eye, and using an incorrect amount of drops. There was a large discrepancy between the patients' perceptions and the observed technique of drop administration.

FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.

Для цитирования: An Jella Angela, Kasner Oscar, Samek Deborah Anne, Lévesque Valérie. Evaluation of eyedrop administration by inexperienced patients after cataract surgery.. Journal of cataract and refractive surgery. 2014. DOI: 10.1016/j.jcrs.2014.02.037.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.