Visual and optical performance of diffractive multifocal intraocular lenses with different haptic designs: 6 month follow-up.

Wang Mengmeng, Corpuz Christine Carole C, Fujiwara Megumi, Tomita Minoru

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate and compare the visual acuity outcomes and optical performances of eyes implanted with two diffractive multifocal intraocular lens (IOL) models with either a plate haptic design or a modified-C design.

METHODS

This retrospective study comprised cataract patients who were implanted with either a plate haptic multifocal IOL model (Acriva(UD) Reviol BB MFM 611 [VSY Biotechnology, Amsterdam, the Netherlands], group 1) or a modified-C haptic multifocal IOL model (Acriva(UD) Reviol BB MF 613 [VSY Biotechnology, Amsterdam, the Netherlands], group 2) between June 2012 and May 2013. The 6 month postoperative visual acuity, refraction, defocus curve, contrast sensitivity, and wave-front aberration were evaluated and compared between these eyes, using different IOL models.

RESULTS

One hundred fifty-eight eyes of 107 patients were included in this study. Significant improvement in visual acuities and refraction was found in both groups after cataract surgery (P<0.01). The visual acuity and contrast sensitivity were statistically better in group 1 than in group 2 (P<0.01). No statistically significant difference in the corneal higher-order aberrations was found between the two groups (P>0.05). However, the ocular higher-order aberrations in group 2 were significantly greater than in group 1 (P<0.05).

CONCLUSION

At 6 months postoperatively, both Acriva(UD) Reviol BB MFM 611 IOL and Acriva(UD) Reviol BB MF 613 IOL achieved excellent visual and refractive outcomes. The multifocal IOL model with plate haptic design resulted in better optical performances than that with the modified-C haptic design.

Для цитирования: Wang Mengmeng, Corpuz Christine Carole C, Fujiwara Megumi, Tomita Minoru. Visual and optical performance of diffractive multifocal intraocular lenses with different haptic designs: 6 month follow-up.. Clinical ophthalmology (Auckland, N.Z.). 2014. DOI: 10.2147/opth.s60493.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.