MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/opx.0000000000000190

Медицинская библиотека · Optometry and vision science : official publication of the American Academy of Optometry · 2014

Double-pass system assessing the optical quality of pseudophakic eyes.

Lee Hun, Lee Kwanghyun, Ahn Ji Min, Kim Eung Kweon, Sgrignoli Bradford, Kim Tae-Im

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the optical quality measurements obtained from the double-pass system and ocular aberrations, subjective visual acuity, and contrast sensitivity score in pseudophakic eyes.

METHODS

Three months after cataract surgery, modulation transfer function (MTF) cutoff frequency, Strehl ratio, objective scatter index, and objective pseudoaccommodation obtained from the double-pass system were compared with total aberration, higher-order aberration, and spherical aberration obtained from ray-tracing aberrometer. In addition, parameters of the double-pass system were compared with subjective visual acuity and the contrast sensitivity score.

RESULTS

Forty eyes of 40 patients were included. The MTF cutoff frequency and Strehl ratio were negatively correlated with total aberration (r = -0.503, p = 0.003; r = -0.509, p = 0.003, respectively) and subjective visual acuity (r = -0.453, p = 0.007; r = -0.354, p = 0.040, respectively). The objective scatter index was positively correlated with total aberration (r = 0.451, p = 0.024) and subjective visual acuity (r = 0.516, p = 0.008). The MTF cutoff frequency showed a correlation with contrast sensitivity score under photopic and mesopic conditions.

CONCLUSIONS

Optical quality parameters obtained from the double-pass system were correlated with ocular aberrations, subjective visual acuity, and contrast sensitivity score in pseudophakic eyes.

Для цитирования: Lee Hun, Lee Kwanghyun, Ahn Ji Min, Kim Eung Kweon, Sgrignoli Bradford, Kim Tae-Im. Double-pass system assessing the optical quality of pseudophakic eyes.. Optometry and vision science : official publication of the American Academy of Optometry. 2014. DOI: 10.1097/opx.0000000000000190.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.