Maedel Sophie, Hirnschall Nino, Chen Yen-An, Findl Oliver
Аннотация
PURPOSE: To evaluate the effect of a heparin-coated foldable intraocular lens (IOL) on postoperative flare in high-risk patients.
SETTING: Vienna Institute for Research in Ocular Surgery, Department of Ophthalmology, Hanusch Hospital, Vienna, Austria.
DESIGN: Randomized clinical trial.
METHODS: This study included patients with diabetes mellitus (DM), pseudoexfoliation syndrome (PXF), or both scheduled for cataract surgery in both eyes. One eye received a coated IOL (Polylens EC-1YH PAL) and the other eye, an uncoated control IOL (Polylens EC-1Y PAL). Aqueous flare measurements were taken using a laser flare meter (FM-600, Kowa) preoperatively and 1 hour, 1 day, 3 weeks, and 3 months postoperatively. Visual acuity and anterior (ACO) and posterior (PCO) capsule opacification were assessed, and IOL centration and tilt were measured with a Purkinje meter.
RESULTS: Eighty eyes of 40 patients were included in the study; 64 eyes of 32 patients completed the study. The mean flare values (photons/ms) preoperatively and 1 hour, 1 day, 3 weeks, and 3 months postoperatively were 6.98 ± 3.71 (SD), 19.14 ± 18.90, 16.62 ± 25.33, 10.33 ± 9.70, 8.74 ± 4.64, respectively, with the coated IOL and 8.65 ± 5.73, 22.08 ± 16.23, 13.44 ± 13.71, 7.50 ± 4.11, and 7.03 ± 3.70, respectively, with the control IOL. No significant differences were found in flare, visual acuity, ACO, PCO, tilt, or centration between the coated IOL and the control IOL at any timepoint.
CONCLUSION: No significant differences in flare or capsule performance were found between the coated IOL and control IOL.
SETTING: Vienna Institute for Research in Ocular Surgery, Department of Ophthalmology, Hanusch Hospital, Vienna, Austria.
DESIGN: Randomized clinical trial.
METHODS: This study included patients with diabetes mellitus (DM), pseudoexfoliation syndrome (PXF), or both scheduled for cataract surgery in both eyes. One eye received a coated IOL (Polylens EC-1YH PAL) and the other eye, an uncoated control IOL (Polylens EC-1Y PAL). Aqueous flare measurements were taken using a laser flare meter (FM-600, Kowa) preoperatively and 1 hour, 1 day, 3 weeks, and 3 months postoperatively. Visual acuity and anterior (ACO) and posterior (PCO) capsule opacification were assessed, and IOL centration and tilt were measured with a Purkinje meter.
RESULTS: Eighty eyes of 40 patients were included in the study; 64 eyes of 32 patients completed the study. The mean flare values (photons/ms) preoperatively and 1 hour, 1 day, 3 weeks, and 3 months postoperatively were 6.98 ± 3.71 (SD), 19.14 ± 18.90, 16.62 ± 25.33, 10.33 ± 9.70, 8.74 ± 4.64, respectively, with the coated IOL and 8.65 ± 5.73, 22.08 ± 16.23, 13.44 ± 13.71, 7.50 ± 4.11, and 7.03 ± 3.70, respectively, with the control IOL. No significant differences were found in flare, visual acuity, ACO, PCO, tilt, or centration between the coated IOL and the control IOL at any timepoint.
CONCLUSION: No significant differences in flare or capsule performance were found between the coated IOL and control IOL.
Предметные рубрики MeSH
AgedAged, 80 and overAqueous HumorCoated Materials, BiocompatibleDouble-Blind MethodFemaleFibrinolytic AgentsHeparinHumansInflammationLens Capsule, CrystallineLens Implantation, IntraocularLenses, IntraocularMaleMiddle AgedPhacoemulsificationPostoperative ComplicationsProspective StudiesUveitis, AnteriorVisual Acuity