MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.prevetmed.2026.106783

Медицинская библиотека · Preventive veterinary medicine · 2026

Relative accuracy of point-of-care tests to rule-in heartworm infection in clinically suspected dogs using Bayesian latent class modelling.

Atkinson P J, Quimby C, Datt A, Nielsen T D, Caraguel C G B

СтатьяПеревод в очереди

Аннотация

Our prospective cross-sectional survey of dogs from Western Fiji aimed to evaluate the fitness of common diagnostic test modalities to rule-in Dirofilaria immitis infection in patients with suggestive clinical history or signs. In the absence of a perfect reference standard, we used latent class modelling to evaluate the relative diagnostic accuracy of two point-of-care (POC) detection modalities - the modified Knott's test (MKT) to detect circulating microfilaria and four antigen lateral flow immunoassays (LFI): Anigen Rapid Canine HW Ag Test® (Bionote Co.), SNAP® Heartworm RT Test (IDEXX Laboratories), trūRapid Heartworm (Heska), WITNESS Dirofilaria® (Zoetis Inc.). The tests' fitness for ruling-in infection were compared using the likelihood ratios of a positive result (LR+). The performances of the MKT and the Anigen Rapid LFI to rule-in infection on fresh blood of clinically suspected dogs were moderate to strong (LR+=13.4, 95 %PCI: 6.7-114.6; LR+=20.2, 95 %PCI: 5.4-138.2; respectively) but not consistently different from each other. The Anigen Rapid, SNAP and truRapid tests consistently provided the strongest evidence to rule-in infection. The LR+ of the WITNESS test was approximately twelve times, nine times and two times lower than the SNAP, truRapid and Anigen Rapid LFIs respectively (Bayesian p-value 0.002, 0.004 and 0.02 respectively). Overall, a positive result from MKT or LFIs is suitable to rule-in infection in dogs raising clinical suspicion and would increase the post-test probability of infection similarly. If veterinarians are choosing between LFIs, they should favour either Anigen Rapid, SNAP and truRapid over WITNESS.

Для цитирования: Atkinson P J, Quimby C, Datt A, Nielsen T D, Caraguel C G B. Relative accuracy of point-of-care tests to rule-in heartworm infection in clinically suspected dogs using Bayesian latent class modelling.. Preventive veterinary medicine. 2026. DOI: 10.1016/j.prevetmed.2026.106783.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.