Efficacy of different respiratory supports to prevent hypoxia during flexible bronchoscopy in patients of COPD: a triple-arm, randomised controlled trial.

Sharma Vinod Kumar, Singh Pawan Kumar, Govindagoudar Manjunath B, Thulasi Athul, Chaudhry Dhruva, Shriram Chaudhari Pramod, Lalwani Lokesh Kumar, Ahuja Aman

Рандомизированное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Patients with chronic-obstructive-pulmonary-disease (COPD) undergo bronchoscopy for various reasons, and are at relatively higher risk of complications. This study evaluated the efficacy of non-invasive ventilation (NIV) and high-flow-oxygen-therapy (HFOT) compared with conventional-oxygen-therapy (COT) in patients with COPD undergoing bronchoscopy, to prevent hypoxia.

METHODS

It was a triple-arm, open-label, randomised controlled trial. Ninety patients with COPD were randomly assigned into three intervention arms in 1:1:1 ratio. The incidence of hypoxia, lowest recorded oxygen saturation measured by plethysmography (SpO2), ECG, patient vitals and comfort levels were assessed.

RESULTS

Mean age of the study population was 61.71±7.5 years. Out of 90 cases enrolled, 51, 34 and 5 were moderate, severe and very-severe COPD, respectively, as per GOLD (Global Initiative for Chronic Obstructive Lung Disease) classification. Rest of the baseline characteristics were similar. SpO2 during flexible bronchoscopy (FB) was lowest in COT group (COT: 87.03±5.7% vs HFOT: 95.57±5.0% vs NIV: 97.40±1.6%, p<0.001). Secondary objectives were similar except respiratory-rate (breaths-per-minute) which was highest in COT group (COT: 20.23±3.1 vs HFOT: 18.57±4.1 vs NIV: 16.80±1.9, p<0.001). Whereas post FB partial of oxygen in arterial blood was highest in NIV group (NIV: 84.27±21.6 mm Hg vs HFOT: 69.03±13.6 mm Hg vs COT: 69.30±11.9 mm Hg, p<0.001). Post FB partial pressure of carbon dioxide in arterial blood was similar in the three arms. Operator's ease-of-performing-procedure was least in the NIV group as assessed with Visual Analogue Scale (p<0.01). A higher number of NIV group participants reported nasal pain as compared with the other two arms (p<0.01).

CONCLUSION

NIV and HFOT are superior to COT in preventing hypoxia during bronchoscopy, but NIV is associated with poor patient-tolerance and inferior operator's ease of doing procedure.

TRIAL REGISTRATION NUMBER: CTRI/2021/03/032190.

Для цитирования: Sharma Vinod Kumar, Singh Pawan Kumar, Govindagoudar Manjunath B, Thulasi Athul, Chaudhry Dhruva, Shriram Chaudhari Pramod, Lalwani Lokesh Kumar, Ahuja Aman. Efficacy of different respiratory supports to prevent hypoxia during flexible bronchoscopy in patients of COPD: a triple-arm, randomised controlled trial.. BMJ open respiratory research. 2023. DOI: 10.1136/bmjresp-2022-001524.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.