MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.chroma.2020.461717

Медицинская библиотека · Journal of chromatography. A · 2020

Development of retention time indices for comprehensive multidimensional gas chromatography and application to ignitable liquid residue mapping in wildfire investigations.

Boegelsack Nadin, Sandau Court, McMartin Dena W, Withey Jonathan M, O'Sullivan Gwen

СтатьяПеревод пока не подготовлен

Аннотация

In this study, we introduce a simple three-step workflow for a universally applicable RI system, to be used in GC×GC analysis of ignitable liquid residue (ILR) for arson investigations. The proposed RI system applies a combination of two well-established GC RI systems: non-isothermal Kovats (K) index in the first dimension and Lee (L) index in the second dimension. The proposed KLI RI system showed very good correlations when compared with predicted values and existing RI systems (r2 = 0.97 in first dimension, r2 = 0.99 in second dimension) and was valid for a wide range of analyte concentrations and operational settings (coefficient of variance (CV) < 1% in first dimension, < 10% in second dimension). Using the KLI RI, an ILR classification contour map was created to assist with the identification of ILR types within ASTM E1618. The contour map was successfully applied to neat fuels and a fire scene sample, highlighting the application to wildfire investigation. Standardizing the RI process and establishing acceptable error margins allows the exploration and comparison of comprehensive data generated from GC×GC analysis of ILRs regardless of location, time, or system, further enhancing comprehensive and tenable chemometric analyses of samples. Overall, the KLI workflow was inexpensive, quick to apply, and user-friendly with its simple 3-step design.

Для цитирования: Boegelsack Nadin, Sandau Court, McMartin Dena W, Withey Jonathan M, O'Sullivan Gwen. Development of retention time indices for comprehensive multidimensional gas chromatography and application to ignitable liquid residue mapping in wildfire investigations.. Journal of chromatography. A. 2020. DOI: 10.1016/j.chroma.2020.461717.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.