Cyclic socket enlargement and reduction during walking to minimize limb fluid volume loss in transtibial prosthesis users.

Ballesteros Daniel, Youngblood Robert T, Vamos Andrew C, Garbini Joseph L, Allyn Katheryn J, Hafner Brian J, Larsen Brian G, Ciol Marcia A, Friedly Janna L, Sanders Joan E

СтатьяПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

The purpose of this research was to pursue an innovative cyclic panel-pull strategy during ambulation to minimize limb fluid volume loss in transtibial prosthesis users. Participants' traditional socket shapes were duplicated, and test sockets prepared with three adjustable motor-driven panels that were controlled by a microprocessor. After donning the prosthesis, participants' liners were fastened to the panels. During a 40 min test session, participants conducted three cycles of sitting (5 min) and walking (8 min). During the 5th and 6th min of each cycle of walking, the panels were cyclically pulled outward in late stance phase, decreasing pressure on the residual limb. Panels were returned to their original position in swing phase. Eight of twelve participants gained more fluid volume while walking when panel-pull was added than when it was removed. When the liner was uncoupled from the panels and panel-pull was executed, eight of twelve participants gained less fluid volume compared to when the liner was fastened to the panels. Panel-pull may facilitate limb fluid volume retention in transtibial prosthesis users. Efforts to simplify the design so that it can be implemented in long-term testing during at-home use should be considered.

Для цитирования: Ballesteros Daniel, Youngblood Robert T, Vamos Andrew C, Garbini Joseph L, Allyn Katheryn J, Hafner Brian J, Larsen Brian G, Ciol Marcia A, Friedly Janna L, Sanders Joan E. Cyclic socket enlargement and reduction during walking to minimize limb fluid volume loss in transtibial prosthesis users.. Medical engineering & physics. 2022. DOI: 10.1016/j.medengphy.2022.103787.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.