Comparison of histomorphometric and radiographic effects of growth guidance with tension-band devices (eight-Plate and FlexTack) in a pig model.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Sattelberger Julia, Hillebrand Hauke, Gosheger Georg, Laufer Andrea, Frommer Adrien, Appelbaum Sebastian, Abood Ahmed Abdul-Hussein, Gottliebsen Martin, Rahbek Ole, Moller-Madsen Bjarne, Roedl Robert, Vogt Bjoern
Аннотация
Background and purpose - Temporary hemiepiphysiodesis for growth modulation in skeletally immature patients is a long-known technique. Recently the use of tension-band devices has become popular. This study compares 2 tension-band implants (eight-Plate and FlexTack) regarding their effects on the growth plate.Animals and methods - 12 pigs in 2 equally sized groups (A and B) were investigated. The right proximal medial tibia was treated with either eight-Plate or FlexTack. The left tibia of the same pig was treated with the opposite implant. After 9 weeks all implants were removed. Animals in group B were then hosted for another 5 weeks. Histomorphometric analysis of the growth plate was carried out after 9 and 14 weeks, respectively. Radiographs were taken at implantation, removal, and after 14 weeks.Results - Both tension-band devices achieved a statistically significant and clinically relevant growth inhibition, whereas the effect appeared to be more distinct after the use of FlexTack. Implant-related complications or physeal damage was not observed. After implant removal, rebound phenomenon was radiologically observed in all cases. The growth plates treated with eight-Plate showed a paradox reversal of the zonal distributions, with an increase of the proliferative zones at the previously arrested medial aspect of the physis and a decrease laterally.Interpretation - Both eight-Plate and FlexTack proved to be appropriate devices for growth-guiding treatment. The radiographic evaluation showed a change in angular axes after treatment with each implant, while the correction appeared to be faster with FlexTack. The paradox cartilaginous reaction observed after removal of the eight-Plate might be a histopathological correlate for rebound phenomenon.