MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/opth.s541643

Медицинская библиотека · Clinical ophthalmology (Auckland, N.Z.) · 2025

Evaluation of a Modified Single-Stage Continuous Curvilinear Capsulorhexis Technique Using 18-Gauge Needle Decompression in Intumescent Cataracts.

Hoang Trung Kien, Nguyen Huynh Phuc, Phan Van Nam

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the safety and efficacy of a modified anterior capsulorhexis technique using an 18-gauge needle puncture at the peripheral one-third of the anterior capsule to control intralenticular pressure and achieve single-stage continuous curvilinear capsulorhexis (CCC) in intumescent cataract surgery.

METHODS

This prospective, cross-sectional descriptive study included patients with intumescent cataracts indicated for surgery at Saigon Vinh Eye Hospital from August 2024 to March 2025. Before CCC, all patients underwent an 18-gauge needle puncture at the peripheral one-third of the anterior capsule near the main incision.

RESULTS

A total of 99 eyes from 99 patients were included in the study. The mean axial length was 23.12 ± 0.55 mm, anterior chamber depth 2.62 ± 0.43 mm, and lens thickness 4.91 ± 0.72 mm. In 65 patients (65.7%), the milky liquefied cortex escaped into the anterior chamber after the needle puncture. Single-stage CCC was successfully performed in 98 of 99 cases (98.9%) with a mean capsulorhexis diameter of 5.5 ± 0.3 mm. All surgeries were performed using standard phacoemulsification and in-the-bag IOL implantation (100%). Three months post-operatively, all patients had well-centered IOLs with a best-corrected visual acuity (BCVA) ≥ 4/10.

CONCLUSION

An 18-gauge needle puncture at the peripheral one-third of the anterior capsule offers effective decompression, improves safety, and facilitates CCC in patients with intumescent cataracts. This technique is simple, feasible, and highly applicable in clinical practice.

Для цитирования: Hoang Trung Kien, Nguyen Huynh Phuc, Phan Van Nam. Evaluation of a Modified Single-Stage Continuous Curvilinear Capsulorhexis Technique Using 18-Gauge Needle Decompression in Intumescent Cataracts.. Clinical ophthalmology (Auckland, N.Z.). 2025. DOI: 10.2147/opth.s541643.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.