Daryabari Seyed Hashem, Hosseini Imeni Seyyed Morteza, Ghouhestani Mojtaba

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the effect of suction direction on zonular fibers' mechanical behavior using finite element modeling.

SETTING

Laboratory study.

DESIGN

3D finite element model experimental study.

METHODS

A 3D finite element model was developed, including nucleus covered by cortex and capsule. Similar to cataract surgery, a circular rapture was considered at the top of the capsule to apply suction pressure. Finally, zonular fibers were modeled as a continuum body using 3D solid elements (C3D8R). A custom FORTRAN subroutine was implemented to enforce tension-only behavior, mimicking the physiological characteristics of the zonular fibers, which are resistant to tensile but not compressive loads. This method allows for a realistic simulation of zonular mechanics during cortical aspiration.

RESULTS

The suction processes in tangential and normal angles were simulated. The resulting relative displacements between the cortex and capsule, as a criterion of cortex separation, vs the resulting maximum zonule displacements, were recorded in each model. The cortex-capsule relative displacement vs maximum zonule displacement indicated a diagram slope of 0.09 for tangential applying pressure and 0.02 in the case of applying normal pressure.

CONCLUSIONS

The results illustrated that zonular fibers were less tensile in a specific magnitude of cortex-capsule relative displacement under tangential applying pressure, which means that eye zonular fibers have a lower risk of failure until the separation of the lens cortex.

Для цитирования: Daryabari Seyed Hashem, Hosseini Imeni Seyyed Morteza, Ghouhestani Mojtaba. Effect of suction angle on zonular fibers during residual cortex removal in phacoemulsification using finite element modeling.. Journal of cataract and refractive surgery. 2025. DOI: 10.1097/j.jcrs.0000000000001767.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.