MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00261-017-1138-z

Медицинская библиотека · Abdominal radiology (New York) · 2017

Diagnostic value of fourth-generation iterative reconstruction algorithm with low-dose CT protocol in assessment of mesorectal fascia invasion in rectal cancer: comparison with magnetic resonance.

Ippolito Davide, Drago Silvia Girolama, Talei Franzesi C R, Casiraghi Alessandra, Sironi Sandro

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The purpose of the article is to compare the diagnostic performance about radiation dose and image quality of low-dose CT with iterative reconstruction algorithm (iDose4) and standard-dose CT in the assessment of mesorectal fascia (MRF) invasion in rectal cancer patients.

MATERIALS AND

METHODS

Ninety-one patients with biopsy-proven primary rectal adenocarcinoma underwent CT staging: 42 underwent low-dose CT, 49 underwent standard CT protocol. Low-dose contrast-enhanced MDCT scans were performed on a 256 (ICT, Philips) scanner using 120 kV, automated mAs modulation, iDose4 iterative reconstruction algorithm. Standard-dose MDCT scans were performed on the same scanner with 120 kV, 200-300 mAs. All patients underwent a standard lower abdomen MR study (on 1.5T magnet), including multiplanar sequences, considered as reference standard. Diagnostic accuracy of MRF assessment was determined on CT images for both CT protocols and compared with MRI images. Dose-length product (DLP) and CT dose index (CTDI) calculated for both groups were compared and statistically analyzed.

RESULTS

Low-dose protocol with iDose4 showed high diagnostic quality in assessment of MRF with significant reduction (23%; p = 0.0081) of radiation dose (DLP 2453.47) compared to standard-dose examination (DLP 3194.32).

CONCLUSIONS

Low-dose protocol combined with iDose4 reconstruction algorithm offers high-quality images, obtaining significant radiation dose reduction, useful in the evaluation of MRF involvement in rectal cancer patients.

Для цитирования: Ippolito Davide, Drago Silvia Girolama, Talei Franzesi C R, Casiraghi Alessandra, Sironi Sandro. Diagnostic value of fourth-generation iterative reconstruction algorithm with low-dose CT protocol in assessment of mesorectal fascia invasion in rectal cancer: comparison with magnetic resonance.. Abdominal radiology (New York). 2017. DOI: 10.1007/s00261-017-1138-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.