Long-term monitoring of arrhythmias with cardiovascular implantable electronic devices in patients with cardiac sarcoidosis.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Bakker Annelies, Mathijssen Harold, Dorland Galina, Balt Jippe C, van Dijk Vincent F, Veltkamp Marcel, Akdim Fatima, Grutters Jan C, Post Martijn C
Аннотация
BACKGROUND: Risk stratification for sudden cardiac death (SCD) in cardiac sarcoidosis (CS) is challenging in patients without overt cardiac symptoms.
OBJECTIVE: The purpose of this study was to determine the incidence of ventricular arrhythmias (VAs) and mortality after long-term monitoring with a cardiovascular implantable electronic device (CIED) in CS patients identified after systematic screening of patients with extracardiac sarcoidosis (ECS).
METHODS: A retrospective study was performed in 547 predominantly Caucasian patients with ECS screened for cardiac involvement. If CS was diagnosed, risk stratification (high vs low risk) for SCD was performed by a multidisciplinary team. The primary endpoint was defined as sustained VA, appropriate implantable cardioverter-defibrillator (ICD) therapy, or cardiac death.
RESULTS: In total, 105 patients were included (mean follow-up 33 ± 16 months). An ICD was implanted in 17 high-risk patients (16.2%), whereas 80 low-risk patients (76.1%) received an implantable loop recorder (ILR). Eight low-risk patients (7.6%) did not receive a device. The primary endpoint occurred in 4.8% (n = 5), with an overall annualized event rate of 1.7%. The annualized event rate was 9.8% in high-risk patients and 0.4% in low-risk patients. Nine low-risk patients received an ICD during follow-up, in 7 patients as a result of the ILR recordings. None of these patients required ICD therapy.
CONCLUSION: In CS patients without overt cardiac symptoms at initial presentation the annualized overall event rate was 1.7%; 10% in high-risk patients, but only 0.4% in low-risk patients. In low-risk patients long-term arrhythmia monitoring with an ILR enabled early detection of clinically important arrhythmias without showing impact on prognosis.
OBJECTIVE: The purpose of this study was to determine the incidence of ventricular arrhythmias (VAs) and mortality after long-term monitoring with a cardiovascular implantable electronic device (CIED) in CS patients identified after systematic screening of patients with extracardiac sarcoidosis (ECS).
METHODS: A retrospective study was performed in 547 predominantly Caucasian patients with ECS screened for cardiac involvement. If CS was diagnosed, risk stratification (high vs low risk) for SCD was performed by a multidisciplinary team. The primary endpoint was defined as sustained VA, appropriate implantable cardioverter-defibrillator (ICD) therapy, or cardiac death.
RESULTS: In total, 105 patients were included (mean follow-up 33 ± 16 months). An ICD was implanted in 17 high-risk patients (16.2%), whereas 80 low-risk patients (76.1%) received an implantable loop recorder (ILR). Eight low-risk patients (7.6%) did not receive a device. The primary endpoint occurred in 4.8% (n = 5), with an overall annualized event rate of 1.7%. The annualized event rate was 9.8% in high-risk patients and 0.4% in low-risk patients. Nine low-risk patients received an ICD during follow-up, in 7 patients as a result of the ILR recordings. None of these patients required ICD therapy.
CONCLUSION: In CS patients without overt cardiac symptoms at initial presentation the annualized overall event rate was 1.7%; 10% in high-risk patients, but only 0.4% in low-risk patients. In low-risk patients long-term arrhythmia monitoring with an ILR enabled early detection of clinically important arrhythmias without showing impact on prognosis.