MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/md.0000000000033900

Медицинская библиотека · Medicine · 2023

Comparison between cone-beam breast-CT and full-field digital mammography for microcalcification detection depending on breast density.

Wienbeck Susanne, Andrijevska Viktorija, Kück Fabian, Perske Christina, Unterberg-Buchwald Christina, Fischer Uwe, Lotz Joachim, Kunze Meike

СтатьяПеревод пока не подготовлен

Аннотация

The purpose of this study was to evaluate the impact of breast density on the diagnostic performance of cone-beam breast-CT (CBBCT) in comparison to full-field digital mammography (FFDM) for the detection of microcalcifications. This retrospective IRB-approved study was conducted between December 2015 and March 2017 and enrolled 171 women with Breast Imaging Reporting and Data System category 4 or 5 lesions on FFDM and additional CBBCT; 56 of which were ineligible. The inclusion was restricted to 83 women (90 breasts, 90 lesions) with microcalcifications. All lesions underwent histology or were monitored by FFDM and a clinical examination at least 2 years after enrollment. Two breast radiologists independently read each data set twice. Sensitivity, specificity and area under the curve were compared between the modalities. Thirty-two breasts (35.5%) were grouped as non-dense breasts (American College of Radiology types a/b) and 58 breasts (64.5%) as dense breasts (American College of Radiology types c/d). Histopathological assessment was performed in 61 of 90 breast lesions (32 malignant, 1 high-risk and 28 benign). Area under the curve was larger for FFDM than for CBBCT (P = .085). The sensitivity was significantly higher for FFDM compared to CBBCT (P = .009). The specificity showed no significant differences comparing FFDM (both readers: 0.62) versus CBBCT (reader 1: 0.76, reader 2: 0.60; P = .192). Inter-observer-reliability on BI-RADS readings was almost perfect for FFDM and moderate for CBBCT (κ = 0.84, κ = 0.54, respectively). Intra-observer agreement was substantial to almost perfect for both methods and readers. Compared with FFDM, CBBCT demonstrated non-comparable results for microcalcification detection in dense and non-dense breasts.

Для цитирования: Wienbeck Susanne, Andrijevska Viktorija, Kück Fabian, Perske Christina, Unterberg-Buchwald Christina, Fischer Uwe, Lotz Joachim, Kunze Meike. Comparison between cone-beam breast-CT and full-field digital mammography for microcalcification detection depending on breast density.. Medicine. 2023. DOI: 10.1097/md.0000000000033900.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.