MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1259/bjr.20230089

Медицинская библиотека · The British journal of radiology · 2023

To what extent are objectively measured mammographic imaging techniques associated with compression outcomes.

Hudson Sue M, Wilkinson Louise S, De Stavola Bianca L, Dos-Santos-Silva Isabel

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To describe the association between objectively measurable imaging techniques and the resulting compression thickness and dose.

METHODS

The study included 80,495 routine screens from the South-West London Breast Screening Service between March 2013 and July 2017. Average compression force, paddle tilt and dose were calculated. The Volpara® DensityTM algorithm was used to estimate pressure, breast volume and density.Linear regression models, using generalized estimating equations (GEEs) to account for clustering by practitioner, assessed the strength of the associations between the imaging compression outcomes, (thickness, dose) and imaging techniques (force, pressure and paddle tilt), adjusting for the subject's characteristics (age, ethnicity, breast volume and percent mammographic density).

RESULTS

Fully adjusted linear regression models showed that compression thickness decreased by ~1 mm (~2% of mean thickness) for every 1daN increase in force and decreased by ~0.8 mm with an increase of 1 kPa of pressure (at median pressure). Increasing pressure above 15 kPa resulted in minimal reduction in thickness. Dose increased with increased force but decreased by ~1% of mean dose with every increase in 1 kPa of pressure. For 1o increase in paddle tilt, the compression thickness increased by ~1.5 mm (~2.5%) and dose increased by ~2.5%, (Pt <0.001 in all cases).

CONCLUSION

Differences in imaging technique are associated with imaging outcome measures (thickness and dose). A better understanding of the association between objective image acquisition parameters and tumour conspicuity could lead to clearer guidelines for practitioners.

ADVANCES IN KNOWLEDGE: Increased paddle tilt is associated with increased compression thickness and increased dose after adjustment for breast volume and force applied.

Для цитирования: Hudson Sue M, Wilkinson Louise S, De Stavola Bianca L, Dos-Santos-Silva Isabel. To what extent are objectively measured mammographic imaging techniques associated with compression outcomes.. The British journal of radiology. 2023. DOI: 10.1259/bjr.20230089.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.