OBJECTIVE

To ascertain the utility of residual liquid-preserved cervical cytology samples for DNA profiling studies.

STUDY

DESIGN

Ninety-nine liquid-preserved cervical cytology samples from a high-risk population were received two months after the initial diagnosis at another laboratory. Each residual sample was processed to yield one Papanicolaou-stained and one Feulgen-thionin-stained slide. The former were examined manually without knowledge of the submitted findings and were also examined on the AutoCyte SCREEN interactive system. DNA profiling of > 185 cells per case was performed on an RPW image analyzer. Results were compared with submitted diagnoses.

RESULTS

The 99 cases included 59 normals, 9 ASCUS/AGCUS, 16 HSIL, 12 carcinomas and 3 unsatisfactory. Interlaboratory agreement between residual and initial samples was good (unweighted kappa = .609). Abnormals were characterized by 2C deviation indices > 2.0 and 5C exceeding rates > 4.37%. AutoCyte SCREEN system examination of residual slides of high grade abnormalities was 100% sensitive and 40% specific.

CONCLUSION

Residual AutoCyte cervical cytology samples are stable and yield reproducible results for routine and ancillary studies of cervical cytologic abnormalities. The AutoCyte SCREEN system was 100% sensitive for high grade abnormalities in this enriched sample, even when operating on residual material.

Для цитирования: Bishop J W, Cheuvront D A, Elston R J. Utility of residual AutoCyte cervical cytology samples for image analysis.. Acta cytologica. 1999. DOI: 10.1159/000330867.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.