Peripheral retinal dysfunction in patients taking vigabatrin.

McDonagh J, Stephen L J, Dolan F M, Parks S, Dutton G N, Kelly K, Keating D, Sills G J, Brodie M J

Клиническое исследованиеКонтролируемое клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To assess the wide-field multifocal electroretinogram (WF-mfERG) for assessment of retinal function in vigabatrin-treated patients.

METHODS

Thirty-two adults who had taken vigabatrin for at least 3 years for localization-related epilepsy underwent WF-mfERG, ERG, logMar visual acuity and color vision evaluation, Humphrey visual field analysis (static perimetry), and funduscopy. The group was matched with a cohort of patients who had never received vigabatrin. Results were compared with a normative data set (120 drug-free controls) with respect to potential bilateral abnormalities in response timing.

RESULTS

There were no significant differences between groups in visual acuity or color vision testing. Of the vigabatrin patients, 19 (59%) had bilateral visual field defects compared to none of the controls. Using WF-mfERG, all patients on vigabatrin with visual field defects showed abnormalities (100% sensitivity) and only 2 of the 13 patients without a field defect showed retinal abnormalities (86% specificity).

CONCLUSIONS

WF-mfERG may be useful for detecting retinal pathology in patients taking vigabatrin. The majority of previous reports based on subjective testing may have underestimated the prevalence of peripheral retinal toxicity related to the drug.

Для цитирования: McDonagh J, Stephen L J, Dolan F M, Parks S, Dutton G N, Kelly K, Keating D, Sills G J, Brodie M J. Peripheral retinal dysfunction in patients taking vigabatrin.. Neurology. 2003. DOI: 10.1212/01.wnl.0000098938.80082.25.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.